coolingUnitCIMDeviceId
INTEL-SERVER-BASEBOARD7 ·
.1.3.6.1.4.1.343.2.10.3.5.600.10.1.2
Object
column
SNMPv2-SMIInteger32
This attribute defines the DeviceId used by the Intel CIM software to uniquely identify the device, it represents the [channel#][sensor#][IPMB OwnerID][LUN].
Context
- MIB
- INTEL-SERVER-BASEBOARD7
- OID
.1.3.6.1.4.1.343.2.10.3.5.600.10.1.2- Type
- column
- Access
- readonly
- Status
- current
- Parent
- coolingUnitTableEntry
- Table
- coolingUnitTable
- Siblings
- 6
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| coolingUnitIndex This attribute defines the index (one based) of the cooling unit. | column | OneBasedIndex | .1.3.6.1.4.1.343.2.10.3.5.600.10.1.1 |
| coolingUnitDescription This attribute textually describes the cooling unit. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.343.2.10.3.5.600.10.1.3 |
| coolingUnitStatusString Current status of the sensor will be one of the
following strings: other, unknown, ok, nonCritical, critical, nonRecoverable. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.343.2.10.3.5.600.10.1.4 |
| coolingUnitStatus Current health status of the sensor. | column | IntelStatus | .1.3.6.1.4.1.343.2.10.3.5.600.10.1.5 |
| coolingUnitRedundancyStatus Gives the redundancy status of the Cooling Unit. 'Fully Redundan
' means that all of the configured redundancy is still available; 'Degraded
Redundancy' means that some failures h… | column | IntelRedundancyStatus | .1.3.6.1.4.1.343.2.10.3.5.600.10.1.6 |
| coolingUnitCaption This attribute provides the caption for the cooling unit. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.343.2.10.3.5.600.10.1.7 |