coolingDeviceStatus
INTEL-SERVER-BASEBOARD7 ·
.1.3.6.1.4.1.343.2.10.3.5.600.20.1.5
Object
column
IntelStatus
Current health status of the sensor.
Context
- MIB
- INTEL-SERVER-BASEBOARD7
- OID
.1.3.6.1.4.1.343.2.10.3.5.600.20.1.5- Type
- column
- Access
- readonly
- Status
- current
- Parent
- coolingDeviceTableEntry
- Table
- coolingDeviceTable
- Siblings
- 14
Syntax
IntelStatus
- Source
- IntelStatus
- Base type
Enumeration
Values & Constraints
Type Values
1 | unavailable |
2 | healthy |
3 | warning |
4 | critical |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| coolingDeviceIndex This attribute defines the index (one based) of the cooling device. | column | OneBasedIndex | .1.3.6.1.4.1.343.2.10.3.5.600.20.1.1 |
| coolingDeviceLowerNonCriticalThreshold This attribute contains the lower warning threshold level
for the fan. The threshold is given in the units specified by the Fan Units
attribute. This attribute may not apply to … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.343.2.10.3.5.600.20.1.10 |
| coolingDeviceLowerCriticalThreshold This attribute contains the lower critical threshold level
for the fan. The threshold is given in the units specified by the Fan Units
attribute. This attribute may not apply to … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.343.2.10.3.5.600.20.1.11 |
| coolingDeviceLowerNonRecoverableThreshold This attribute contains the fatal error threshold
level for the fan. The threshold is given in the units specified by the Fan Units
attribute. This attribute may not apply to al… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.343.2.10.3.5.600.20.1.12 |
| coolingDeviceResolution This attribute describes the sensor's resolution. 0x7fffffff (2147483647) denotes 'unknown'. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.343.2.10.3.5.600.20.1.13 |
| coolingDeviceTolerance This attribute describes the sensor's tolerance in
the units specified by the cooling device's units attrubite. 0x7fffffff (2147483647) denotes 'unknown'. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.343.2.10.3.5.600.20.1.14 |
| coolingDeviceAccuracy This attribute describes the sensor's accuracy in
+/- hundredth of a percent. 0x7fffffff (2147483647) denotes 'unknown'. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.343.2.10.3.5.600.20.1.15 |
| coolingDeviceCIMDeviceId This attribute defines the DeviceId used by the Intel CIM software
to uniquely identify the device, it represents the [channel#][sensor#][IPMB OwnerID][LUN]. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.343.2.10.3.5.600.20.1.2 |
| coolingDeviceDescription This attribute textually describes the cooling device. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.343.2.10.3.5.600.20.1.3 |
| coolingDeviceStatusString Current status of the sensor will be one of the
following strings: other, unknown, ok, nonCritical, critical, nonRecoverable. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.343.2.10.3.5.600.20.1.4 |
| coolingDeviceReading This attribute contains the current fan sensor
reading, measured in the units specified by the Fan Units attribute. 0x7fffffff (2147483647) denotes 'unknown'. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.343.2.10.3.5.600.20.1.6 |
| coolingDeviceUpperNonRecoverableThreshold This attribute contains the fatal error threshold
level for the fan. The threshold is given in the units specified by the Fan Units
attribute. This attribute may not apply to al… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.343.2.10.3.5.600.20.1.7 |
| coolingDeviceUpperCriticalThreshold This attribute contains the major error threshold
level for the fan. The threshold is given in the units specified by the Fan Units
attribute. This attribute may not apply to al… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.343.2.10.3.5.600.20.1.8 |
| coolingDeviceUpperNonCriticalThreshold This attribute contains the warning threshold level
for the fan. The threshold is given in the units specified by the Fan Units
attribute. This attribute may not apply to all fa… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.343.2.10.3.5.600.20.1.9 |