iwBrStpBridgeMaxAge

INFINET-BRIDGE-MIB · .1.3.6.1.4.1.3942.1.1.8.1.2.9

Object

scalar r/w centi-seconds Integer32
The value that all bridges use for MaxAge when this
bridge is acting as the root.  Note that the range
for this parameter is related to the value of
iwBrStpBridgeHelloTime. The granularity of this timer
is 1 second. An agent may return a badValue error if
a set is attempted to a value that is not a whole
number of seconds.

Context

MIB
INFINET-BRIDGE-MIB
OID
.1.3.6.1.4.1.3942.1.1.8.1.2.9
Type
scalar
Access
readwrite
Status
current
Units
centi-seconds
Parent
iwBrStp
Siblings
10

Syntax

centi-seconds Integer32

Values & Constraints

Object Constraints
range: 600-4000

Related Objects