ieee8021PSFPOperCycleTimeDenominator
IEEE8021-PSFP-MIB ·
.1.3.111.2.802.1.1.31.1.2.1.1.12
Object
column
SNMPv2-SMIUnsigned32
The operational value of the denominator of the CycleTime parameter for the gate. The numerator and denominator together represent the cycle time as a rational number of seconds.
Context
- MIB
- IEEE8021-PSFP-MIB
- OID
.1.3.111.2.802.1.1.31.1.2.1.1.12- Type
- column
- Access
- readonly
- Status
- current
- Parent
- ieee8021PSFPStreamGateEntry
- Table
- ieee8021PSFPStreamGateTable
- Siblings
- 28
Syntax
SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ieee8021PSFPStreamGateInstance The StreamGateInstance parameter is an index into the
StreamGateTable.
The value of this object MUST be retained across
reinitializations of the management system. | column | SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.31.1.2.1.1.1 |
| ieee8021PSFPAdminCycleTimeDenominator The administrative value of the denominator of the
CycleTime parameter for the gate.
The numerator and denominator together represent the cycle time as
a rational number of secon… | column | SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.31.1.2.1.1.10 |
| ieee8021PSFPOperCycleTimeNumerator The operational value of the numerator of the
CycleTime parameter for the gate.
The numerator and denominator together represent the cycle
time as a rational number of seconds. | column | SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.31.1.2.1.1.11 |
| ieee8021PSFPAdminCycleTimeExtension The administrative value of the CycleTimeExtension
parameter for the gate.
The value is an unsigned integer number of nanoseconds.
The value of this object MUST b… | column | nanoseconds SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.31.1.2.1.1.13 |
| ieee8021PSFPOperCycleTimeExtension The operational value of the CycleTimeExtension
parameter for the gate.
The value is an unsigned integer number of nanoseconds. | column | nanoseconds SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.31.1.2.1.1.14 |
| ieee8021PSFPAdminBaseTime The administrative value of the BaseTime parameter for the gate.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit i… | column | PTP time IEEE8021-ST-MIBIEEE8021STPTPtimeValue | .1.3.111.2.802.1.1.31.1.2.1.1.15 |
| ieee8021PSFPOperBaseTime The operationsl value of the BaseTime parameter for the gate.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit inte… | column | PTP time IEEE8021-ST-MIBIEEE8021STPTPtimeValue | .1.3.111.2.802.1.1.31.1.2.1.1.16 |
| ieee8021PSFPConfigChange The ConfigChange parameter signals the start of a
configuration change for the gate
when it is set to TRUE. This should only be done
when the various administrative parameters
ar… | column | SNMPv2-TCTruthValue | .1.3.111.2.802.1.1.31.1.2.1.1.17 |
| ieee8021PSFPConfigChangeTime The PTPtime at which the next config change is scheduled to occur.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit… | column | PTP time IEEE8021-ST-MIBIEEE8021STPTPtimeValue | .1.3.111.2.802.1.1.31.1.2.1.1.18 |
| ieee8021PSFPTickGranularity The granularity of the cycle time clock, represented as an
unsigned number of tenths of nanoseconds.
The value of this object MUST be retained across
reinitializati… | column | SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.31.1.2.1.1.19 |
| ieee8021PSFPGateEnabled The GateEnabled parameter determines whether the stream gate
is active (true) or inactive (false).
The value of this object MUST be retained across
reinitialization… | column | SNMPv2-TCTruthValue | .1.3.111.2.802.1.1.31.1.2.1.1.2 |
| ieee8021PSFPCurrentTime The current time, in PTPtime, as maintained by the local system.
The value is a representation of a PTPtime value,
consisting of a 48-bit integer
number of seconds and a 32-bit i… | column | IEEE8021-ST-MIBIEEE8021STPTPtimeValue | .1.3.111.2.802.1.1.31.1.2.1.1.20 |
| ieee8021PSFPConfigPending The value of the ConfigPending state machine variable.
The value is TRUE if a configuration change is in progress
but has not yet completed. | column | SNMPv2-TCTruthValue | .1.3.111.2.802.1.1.31.1.2.1.1.21 |
| ieee8021PSFPConfigChangeError A counter of the number of times that a re-configuration
of the traffic schedule has been requested with the old
schedule still running and the requested base time was
in the past. | column | SNMPv2-SMICounter64 | .1.3.111.2.802.1.1.31.1.2.1.1.23 |
| ieee8021PSFPAdminIPV The administrative value of the IPV parameter for the gate.
A value of -1 denotes the null value. | column | Integer32 | .1.3.111.2.802.1.1.31.1.2.1.1.24 |
| ieee8021PSFPOperIPV The operational value of the IPV parameter for the gate.
A value of -1 denotes the null value. | column | Integer32 | .1.3.111.2.802.1.1.31.1.2.1.1.25 |
| ieee8021PSFPGateClosedDueToInvalidRxEnable The PSFPGateClosedDueToInvalidRxEnable object contains
a Boolean value that indicates whether the
PSFPGateClosedDueToInvalidRx function is enabled (TRUE) or
disabled (FALSE).
… | column | SNMPv2-TCTruthValue | .1.3.111.2.802.1.1.31.1.2.1.1.26 |
| ieee8021PSFPGateClosedDueToInvalidRx The PSFPGateClosedDueToInvalidRx object contains
a Boolean value that indicates whether, if the
PSFPGateClosedDueToInvalidRx function is enabled,
all frames are to be discarded (… | column | SNMPv2-TCTruthValue | .1.3.111.2.802.1.1.31.1.2.1.1.27 |
| ieee8021PSFPGateClosedDueToOctetsExceededEnable The PSFPGateClosedDueToOctetsExceededEnable object contains
a Boolean value that indicates whether the
PSFPGateClosedDueToOctetsExceeded function is enabled (TRUE)
or disabled (FA… | column | SNMPv2-TCTruthValue | .1.3.111.2.802.1.1.31.1.2.1.1.28 |
| ieee8021PSFPGateClosedDueToOctetsExceeded The PSFPGateClosedDueToOctetsExceeded parameter contains
a Boolean value that indicates whether, if the
PSFPGateClosedDueToOctetsExceeded function is enabled, all
frames are to … | column | SNMPv2-TCTruthValue | .1.3.111.2.802.1.1.31.1.2.1.1.29 |
| ieee8021PSFPAdminGateStates The administrative value of the GateStates parameter for the
stream gate.
The open value indicates that the gate is open,
the closed value indicates that the gate is closed.
… | column | Enumeration | .1.3.111.2.802.1.1.31.1.2.1.1.3 |
| ieee8021PSFPStreamGateEntryRowStatus The status of the row.
The writable columns in a row cannot be changed if the row
is active. All columns MUST have a valid value before a row
can be activated. | column | SNMPv2-TCRowStatus | .1.3.111.2.802.1.1.31.1.2.1.1.30 |
| ieee8021PSFPOperGateStates The operational value of the GateStates parameter for the
stream gate.
The open value indicates that the gate is open,
the closed value indicates that the gate is closed. | column | Enumeration | .1.3.111.2.802.1.1.31.1.2.1.1.4 |
| ieee8021PSFPAdminControlListLength The administrative value of the ListMax parameter for the gate.
The integer value indicates the number of entries (TLVs) in the
AdminControlList.
The value of this … | column | SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.31.1.2.1.1.5 |
| ieee8021PSFPOperControlListLength The operational value of the ListMax parameter for the gate.
The integer value indicates the number of entries (TLVs) in the
OperControlList. | column | SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.31.1.2.1.1.6 |
| ieee8021PSFPAdminControlList The administrative value of the ControlList parameter for the gate.
The octet string value represents the contents of the control list as
an ordered list of entries, each encoded … | column | OctetString | .1.3.111.2.802.1.1.31.1.2.1.1.7 |
| ieee8021PSFPOperControlList The operational value of the ControlList parameter for the gate.
The octet string value represents the contents of the control list as
an ordered list of entries, each encoded as … | column | OctetString | .1.3.111.2.802.1.1.31.1.2.1.1.8 |
| ieee8021PSFPAdminCycleTimeNumerator The administrative value of the numerator of the CycleTime
parameter for the gate.
The numerator and denominator together represent the cycle time as
a rational number of seconds.… | column | SNMPv2-SMIUnsigned32 | .1.3.111.2.802.1.1.31.1.2.1.1.9 |