ieee8021PSFPFilterSpecificationList

IEEE8021-PSFP-MIB · .1.3.111.2.802.1.1.31.1.1.1.1.5

Object

column r/w OctetString
The FilterSpecificationList parameter contains a list of  
filter specifications associated with this stream filter.
              
The octet string value represents the contents of the list as
an ordered list of entries, each encoded as a TLV, as follows.
              
The first octet  of each TLV is interpreted as an
unsigned integer representing a filter specification type:
    0: Maximum SDU Size.
    1: Flow meter instance identifier.
    2-255: Reserved for future gate operations
                  
The second and third octets of the TLV are the length field, 
interpreted as an unsigned integer, indicating the number of
octets of the value that follows the length. A length of
zero indicates that there is no value 
(i.e., the filter specification has no parameters).
              
The fourth through (4 + length -1)th octets encode the 
parameters of the filter specification, as defined for each
filter specification type.
              
- Maximum SDU Size:
    A single SDU size parameter is encoded in four octets, and
    is interpreted as an unsigned integer value.
                  
- Flow meter instance identifier:
    A single flow meter instance identifier is encoded in
    four octets, and is interpreted as an unsigned integer value.
                   
The value of this object MUST be retained across
reinitializations of the management system.

Context

MIB
IEEE8021-PSFP-MIB
OID
.1.3.111.2.802.1.1.31.1.1.1.1.5
Type
column
Access
readwrite
Status
current
Parent
ieee8021PSFPStreamFilterEntry
Table
ieee8021PSFPStreamFilterTable
Siblings
13

Syntax

OctetString

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects