ieee8021MstpPortAdminPathCost

IEEE8021-MSTP-MIB · .1.3.111.2.802.1.1.6.1.4.1.14

Object

column r/w Integer32
In an MSTP Bridge, the administrative value of the Port's
Port Path Cost parameter value for the MSTI.
              
Writing a value of '0' assigns the automatically calculated
default Path Cost value to the Port.  If the default Path
Cost is being used, this object returns '0' when read.
              
This complements the object ieee8021MstpPortPathCost,
which returns the operational value of the path cost.
              
The value of this object MUST be retained across
reinitializations of the management system.

Context

MIB
IEEE8021-MSTP-MIB
OID
.1.3.111.2.802.1.1.6.1.4.1.14
Type
column
Access
readwrite
Status
current
Parent
ieee8021MstpPortEntry
Table
ieee8021MstpPortTable
Siblings
13

Syntax

Integer32

Values & Constraints

Object Constraints
range: 1-200000000

Related Objects

Sibling Objects