coolingDeviceUpperNonRecoverableThreshold

IDRAC-MIB-SMIv2 · .1.3.6.1.4.1.674.10892.5.4.700.12.1.9

Object

0700.0012.0001.0009 This attribute defines the upper nonrecoverable threshold
of the cooling device.  The value is an integer representing fan speed
in revolutions per minute (RPM).  It is not applicable to OFF/ON type
cooling devices or non-cooling device types.

Context

MIB
IDRAC-MIB-SMIv2
OID
.1.3.6.1.4.1.674.10892.5.4.700.12.1.9
Type
column
Access
readonly
Status
current
Parent
coolingDeviceTableEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'IDRAC-MIB-SMIv2' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IDRAC-MIB-SMIv2::coolingDeviceUpperNonRecoverableThreshold'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'IDRAC-MIB-SMIv2' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'IDRAC-MIB-SMIv2::coolingDeviceUpperNonRecoverableThreshold.<coolingDevicechassisIndex>.<coolingDeviceIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'IDRAC-MIB-SMIv2' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'IDRAC-MIB-SMIv2::coolingDeviceUpperNonRecoverableThreshold'

Syntax

Source
Signed32BitRange
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483647..2147483647

Conformance