hwQrydatasyncondition

HUAWEI-SWITCHOVER-MIB · .1.3.6.1.4.1.2011.6.22.1.1.1

Object

scalar Enumeration
The query of the status of data synchronization between 
the active and standby control boards. Data synchronization
between the active and standby control boards refers to 
that when the active and standby control boards work normally. 
The data on the standby control board is synchronized with 
that on the active control board.The data synchronization 
between the active and standby boards has the following status:
Options:          
1. synccompleteness(1)
   -indicates that synchronization complete.
2. flashsyncincompleteness(2) 
   -indicates that operation (loading/backuping/ duplicating/saving/...) is being performed.
3. configbasicdatasyncincompleteness(3) 
   -indicates that configuration data or basic operation data synchronized incompletely.
4. syncswitchoff(4) 
   -indicates that the synchronization switch off.
5. peerboardfailure(5)
   -indicates that the standby board fail.
6. dynamicdatasyncincompleteness(6)
   -indicates that dynamic service data synchronization is incomplete.
7. patchinconsistent(7)
   -indicates that patch files of active board and standby board are inconsistent.
8. patchinconsistentdynamicdatasyncincompleteness(8)
   -indicates that patch files of active board and standby board are inconsistent and 
   dynamic service data synchronization is incomplete.   
9. peerboardoffline(9)
   -indicates that the standby board doesn't exist.

Context

MIB
HUAWEI-SWITCHOVER-MIB
OID
.1.3.6.1.4.1.2011.6.22.1.1.1
Type
scalar
Access
readonly
Status
current
Parent
hwDataswitchover
Siblings
2

Syntax

Enumeration

Values & Constraints

Enumerated Values
1synccompleteness
2flashsyncincompleteness
3configbasicdatasyncincompleteness
4syncswitchoff
5peerboardfailure
6dynamicdatasyncincompleteness
7patchinconsistent
8patchinconsistentdynamicdatasyncincompleteness
9peerboardoffline

Related Objects

Sibling Objects