hwAutoSwitchOverStatus
HUAWEI-SWITCHOVER-MIB ·
.1.3.6.1.4.1.2011.6.22.3.5
Object
scalar
r/w
Enumeration
Status of auto switchover function. If the value of switchover switch hwSwitchOverStatus
is off(2), the system cannot perform the active/standby switchover.
Options:
1.on(1) -indicates that the automatic switchover is enabled. In this case,
if the values of the hwSwitchOverPeriod, hwSwitchOverInverseDayNo,
and hwSwitchOverTime are set, the system performs the automatic switchover periodically;
if the values of the hwSwitchOverPeriod, hwSwitchOverInverseDayNo, and hwSwitchOverTime
are not set or only partially set, the objects that are not set with values use the default
value, and the system also performs the automatic switchover periodically.
2.off(2) -indicates that the automatic switchover is disabled. If this object is not set with a value,
the system does not perform the automatic switchover.
Default { off }
Context
- MIB
- HUAWEI-SWITCHOVER-MIB
- OID
.1.3.6.1.4.1.2011.6.22.3.5- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- hwSwitchOverControl
- Siblings
- 4
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | on |
2 | off |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwSwitchOverStatus The switch of the active/standby switchover.
Options:
1. on(1) -indicates that the active/standby switchover is enabled.
2. off(2) -indicates that the active/standby switchover i… | scalar | Enumeration | .1.3.6.1.4.1.2011.6.22.3.1 |
| hwSwitchOverPeriod The period of the active/standby switchover.
Options:
1. day(1) -indicates that the switchover is performed once a day.
2. week(2) -indicates that the switchover is performed … | scalar | Enumeration | .1.3.6.1.4.1.2011.6.22.3.2 |
| hwSwitchOverInverseDayNo Days since the periodic switchover has been started. Its value
range depends on the value of object hwSwitchOverPeriod.
When hwSwitchOverPeriod is set to day(1), the default valu… | scalar | Integer32 | .1.3.6.1.4.1.2011.6.22.3.3 |
| hwSwitchOverTime Time when switchover will happen. Time is set by a string in the format of hh:mm:ss.
The value range of hh is from 00 to 23. The value range of mm is from 00 to 59.
The value ran… | scalar | OctetString | .1.3.6.1.4.1.2011.6.22.3.4 |