sensorEventReadingType
HUAWEI-SERVER-IBMC-MIB ·
.1.3.6.1.4.1.2011.2.235.1.1.13.50.1.16
Object
column
SNMPv2-SMIInteger32
Information about event reading type.
Context
- MIB
- HUAWEI-SERVER-IBMC-MIB
- OID
.1.3.6.1.4.1.2011.2.235.1.1.13.50.1.16- Type
- column
- Access
- readonly
- Status
- current
- Parent
- sensorDescriptionEntry
- Table
- sensorDescriptionTable
- Siblings
- 15
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sensorName Information about sensor name. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2011.2.235.1.1.13.50.1.1 |
| sensorType Information about sensor type. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.2.235.1.1.13.50.1.10 |
| sensorPositiveHysteresis Positive-going Threshold Hysteresis Value. Set to 00h if sensor does not
support positive-going threshold hysteresis. This value is subtracted from
positive going thresholds to … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.2.235.1.1.13.50.1.11 |
| sensorNegativeHysteresis Negative-going Threshold Hysteresis Value. This value is added to negative
going thresholds to determine the point where the asserted status for that
threshold will clear. Set … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.2.235.1.1.13.50.1.12 |
| sensorPositiveHysteresisString Positive-going Threshold Hysteresis Value. Set to 'na' if sensor does not
support positive-going threshold hysteresis. This value is subtracted from
positive going thresholds to… | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2011.2.235.1.1.13.50.1.13 |
| sensorNegativeHysteresisString Negative-going Threshold Hysteresis Value. This value is added to negative
going thresholds to determine the point where the asserted status for that
threshold will clear. Set … | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2011.2.235.1.1.13.50.1.14 |
| sensorUnit Information about sensor unit. | column | Enumeration | .1.3.6.1.4.1.2011.2.235.1.1.13.50.1.15 |
| sensorReading Sensor current reading. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2011.2.235.1.1.13.50.1.2 |
| sensorUpperNonRecoverable Information about sensor upper nonrecoverable threshold. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2011.2.235.1.1.13.50.1.3 |
| sensorUpperCritical Information about sensor upper crtical threshold. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2011.2.235.1.1.13.50.1.4 |
| sensorUpperMinor Information about sensor upper minor threshold. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2011.2.235.1.1.13.50.1.5 |
| sensorLowerNonRecoverable Information about sensor lower nonrecoverable threshold. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2011.2.235.1.1.13.50.1.6 |
| sensorLowerCritical Information about sensor lower crtical threshold. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2011.2.235.1.1.13.50.1.7 |
| sensorLowerMinor Information about sensor lower minor threshold. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2011.2.235.1.1.13.50.1.8 |
| sensorStatus Information about sensor status. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.2011.2.235.1.1.13.50.1.9 |