hwRegisterIncomingSignalType
HUAWEI-R2-MIB ·
.1.3.6.1.4.1.2011.6.108.1.2.1.18
Object
column
r/w
Enumeration
Signaling type of incoming office register Options: 1. mfc(1)-the register incoming signal type is mfc 2. pulse(2) -the register incoming signal type is pulse 3. dtmf(3) -the register incoming signal type is dtmf 4. mfp(4) -the register incoming signal type is mfp 5. dpmfp(5) -the register incoming signal type is dpmfp
Context
- MIB
- HUAWEI-R2-MIB
- OID
.1.3.6.1.4.1.2011.6.108.1.2.1.18- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hwRegisterSignalAttributeEntry
- Table
- hwRegisterSignalAttributeTable
- Siblings
- 17
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | mfc |
2 | pulse |
3 | dtmf |
4 | mfp |
5 | dpmfp |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwRegisterSignalIndex R2 signaling profile index | column | Integer32 | .1.3.6.1.4.1.2011.6.108.1.2.1.1 |
| hwReceiveNumberMaxInterval obsolete Max. interval of receiving calling(callee) signals (s) | column | Integer32 | .1.3.6.1.4.1.2011.6.108.1.2.1.10 |
| hwSignalStopPermitTime obsolete Max. duration of signal interruption | column | Integer32 | .1.3.6.1.4.1.2011.6.108.1.2.1.11 |
| hwWaitCallerCategoryTime Wait time for receiving calling party type (s) | column | Integer32 | .1.3.6.1.4.1.2011.6.108.1.2.1.12 |
| hwWaitBsignalTime Wait time for receiving group B signal (s) | column | Integer32 | .1.3.6.1.4.1.2011.6.108.1.2.1.13 |
| hwNumberSendMode Signal transmit mode
Options:
1. immediate(1)- number send immediately
2. delay(2) - number send delay | column | Enumeration | .1.3.6.1.4.1.2011.6.108.1.2.1.14 |
| hwCallingNumberMaxLength Max. length of calling number | column | Integer32 | .1.3.6.1.4.1.2011.6.108.1.2.1.15 |
| hwCompellingSequenceKeepaliveTime Compelling sequence keepalive time for register signaling (ms) | column | Integer32 | .1.3.6.1.4.1.2011.6.108.1.2.1.16 |
| hwSendPulseSignal Whether to send sending-finished signals
Options:
1. yes(1)- send pulse signal
2. no(2) - do not send pulse signal | column | Enumeration | .1.3.6.1.4.1.2011.6.108.1.2.1.17 |
| hwRegisterOutgoingSignalType Signaling type of outgoing office register
Options:
1. mfc(1)-the register outgoing signal type is mfc
2. pulse(2) -the register outgoing signal type is pulse
3. dtmf(… | column | Enumeration | .1.3.6.1.4.1.2011.6.108.1.2.1.2 |
| hwSignalSendVoltage Register signal transmit level(dbm)
1:-25dBm
2:-24dBm
3:-23dBm
4:-22dBm
5:-21dBm
6:-20dBm
7:-19dBm
8:-18dBm
9:-17dBm
10:-16dBm
11:-15dBm
12:-14dBm
13:-13dBm
14:-12dBm
15:-11dBm
16… | column | Integer32 | .1.3.6.1.4.1.2011.6.108.1.2.1.3 |
| hwBackPulseTime Backword pulse duration(Multiple of 10; unit: ms) | column | Integer32 | .1.3.6.1.4.1.2011.6.108.1.2.1.4 |
| hwDTMFSendTime DTMF signal transmit duration (ms) | column | Integer32 | .1.3.6.1.4.1.2011.6.108.1.2.1.5 |
| hwDTMFSendInterval DTMF signal transmit interval (ms) | column | Integer32 | .1.3.6.1.4.1.2011.6.108.1.2.1.6 |
| hwNoCallerPermit obsolete Can the call be established without a calling party
Options:
1. yes(1)- permit send caller number
2. no(2) - not permit send caller number | column | Enumeration | .1.3.6.1.4.1.2011.6.108.1.2.1.7 |
| hwNumberMaxInterval Max. dialing interval (s) | column | Integer32 | .1.3.6.1.4.1.2011.6.108.1.2.1.8 |
| hwSignalKeepMaxTime obsolete Max. signal duration (s) | column | Integer32 | .1.3.6.1.4.1.2011.6.108.1.2.1.9 |