When the MSTP process stop functioning as a root bridge, an alarm message is generated. 
Cause: The MSTP process can no longer play the role of the root bridge because another MSTP process with a higher priority becomes the root bridge. 
Solution: Reduce the priority of the new root bridge on the specified MSTI if you do not want another MSTP process to function as the root bridge. 
On the contrary, delete the setting of the original root bridge on the specified MSTI if you want the new MSTP process to function as the root bridge.