hwXponOntDdmInfoExModuleType
HUAWEI-LINE-COMMON-MIB ·
.1.3.6.1.4.1.2011.6.158.1.1.1.2.1.30
Object
column
Enumeration
Options: 1. gpon(1) - GPON 2. epon(2) - EPON 3. epon10g(3) - 10G EPON 4. gpon10g(4) - 10G GPON 5. wdmpon(5) - WDM PON 6. hybridpon(6) - hybrid PON 7. gponepon(7) - GPON/EPON 8. unknown(8) - Unknown 9. xgspon(9) - XGS-PON 10.twdmpon(15) - TWDM-PON 11.invalid(-1) - Indicates that the query fails or no information is detected
Context
- MIB
- HUAWEI-LINE-COMMON-MIB
- OID
.1.3.6.1.4.1.2011.6.158.1.1.1.2.1.30- Type
- column
- Access
- readonly
- Status
- current
- Parent
- hwXponDeviceOntDdmInfoExEntry
- Table
- hwXponDeviceOntDdmInfoExTable
- Siblings
- 39
Syntax
Enumeration
Values & Constraints
Enumerated Values
-1 | invalid |
1 | gpon |
2 | epon |
3 | epon10g |
4 | gpon10g |
5 | wdmpon |
6 | hybridpon |
7 | gponepon |
8 | unknown |
9 | xgspon |
15 | twdmpon |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwXponOntDdmInfoExOntIndex ONT ID, range: 0-127 | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.1 |
| hwXponOntDdmInfoExSupplyVoltageHighWarningThreshold Upper warning threshold of the voltage.
Unit: 0.000001V
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.10 |
| hwXponOntDdmInfoExSupplyVoltageLowWarningThreshold Lower warning threshold of the voltage.
Unit: 0.000001V
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.11 |
| hwXponOntDdmInfoExTxBiasCurrent Current of the optical transceiver on the ONT.
Unit: 0.000001A
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.000001A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.12 |
| hwXponOntDdmInfoExTxBiasCurrentHighAlarmThreshold Upper alarm threshold of the bias current.
Unit: 0.000001A
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.000001A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.13 |
| hwXponOntDdmInfoExTxBiasCurrentLowAlarmThreshold Lower alarm threshold of the bias current.
Unit: 0.000001A
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.000001A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.14 |
| hwXponOntDdmInfoExTxBiasCurrentHighWarningThreshold Upper warning threshold of the bias current.
Unit: 0.000001A
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.000001A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.15 |
| hwXponOntDdmInfoExTxBiasCurrentLowWarningThreshold Lower warning threshold of the bias current.
Unit: 0.000001A
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.000001A SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.16 |
| hwXponOntDdmInfoExTxPower Tx optical power of the optical transceiver on the ONT.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.17 |
| hwXponOntDdmInfoExTxPowerHighAlarmThreshold Upper alarm threshold of the Tx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.18 |
| hwXponOntDdmInfoExTxPowerLowAlarmThreshold Lower alarm threshold of the Tx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.19 |
| hwXponOntDdmInfoExTemperature Temperature of the optical transceiver on the ONT.
Unit: 0.000001 C(centigrade)
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001 C(centigrade) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.2 |
| hwXponOntDdmInfoExTxPowerHighWarningThreshold Upper warning threshold of the Tx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.20 |
| hwXponOntDdmInfoExTxPowerLowWarningThreshold Lower warning threshold of the Tx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.21 |
| hwXponOntDdmInfoExRxPower Rx optical power of the optical transceiver on the ONT.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.22 |
| hwXponOntDdmInfoExRxPowerHighAlarmThreshold Upper alarm threshold of the Rx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.23 |
| hwXponOntDdmInfoExRxPowerLowAlarmThreshold Lower alarm threshold of the Rx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.24 |
| hwXponOntDdmInfoExRxPowerHighWarningThreshold Upper warning threshold of the Rx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.25 |
| hwXponOntDdmInfoExRxPowerLowWarningThreshold Lower warning threshold of the Rx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.26 |
| hwXponOntDdmInfoExOltRxOntPower threshold of the ont Tx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.27 |
| hwXponOntDdmInfoExCatvRxPowerHighAlarmThreshold Upper AlarmThreshold threshold of the CATV Rx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.28 |
| hwXponOntDdmInfoExCatvRxPowerLowAlarmThreshold Lower AlarmThreshold threshold of the CATV Rx power.
Unit: 0.000001dBm
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.29 |
| hwXponOntDdmInfoExTemperatureHighAlarmThreshold Upper alarm threshold of the temperature.
Unit: 0.000001 C(centigrade)
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001 C(centigrade) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.3 |
| hwXponOntDdmInfoExSubType Options:
1. classbplus(1) - CLASS B+
2. classcplus(2) - CLASS C+
3. classb(3) - CLASS B
4. classcplusplus(4) - CLASS C++
5.… | column | Enumeration | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.31 |
| hwXponOntDdmInfoExPrecision This object indicates the precision of optical power.
Unit: 0.1dBm
Options:
1. invalid(-1) - Indicates that the query fails or no information is detected | column | 0.1dBm SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.32 |
| hwXponOntDdmInfoExEncapsulationType Options:
1. sff2x5(1) - SFF 2x5
2. sff2x10(2) - SFF 2x10
3. sfp(3) - SFP
4. xfp(4) - XFP
5. lxfp(5) - … | column | Enumeration | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.33 |
| hwXponOntDdmInfoExVendorPN This object indicates the part number. | column | OctetString | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.34 |
| hwXponOntDdmInfoExUsedType This object indicates the application scenario of the optical transceiver.
Options:
1. olt(1) - OLT
2. onu(3) - ONU
3. catvtriplex(4) - CAT… | column | Enumeration | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.35 |
| hwXponOntDdmInfoExPortId This object indicates the ID of the ONT PON port where the optical module is located.
It is numbered from 0.
Options:
1. invalid(-1) - Indicates that the query fails or no … | column | Integer32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.36 |
| hwXponOntDdmInfoExVendorName This object indicates the SFP vendor name (ASCII). | column | OctetString | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.37 |
| hwXponOntDdmInfoExVendorRev This object indicates the revision level for part number provided by vendor (ASCII). | column | OctetString | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.38 |
| hwXponOntDdmInfoExVendorSN This object indicates the serial number provided by vendor (ASCII). | column | OctetString | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.39 |
| hwXponOntDdmInfoExTemperatureLowAlarmThreshold Lower alarm threshold of the temperature.
Unit: 0.000001 C(centigrade)
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001 C(centigrade) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.4 |
| hwXponOntDdmInfoExDateCode This object indicates manufacturing date code of the vendor (ASCII). | column | OctetString | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.40 |
| hwXponOntDdmInfoExTemperatureHighWarningThreshold Upper warning threshold of the temperature.
Unit: 0.000001 C(centigrade)
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001 C(centigrade) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.5 |
| hwXponOntDdmInfoExTemperatureLowWarningThreshold Lower warning threshold of the temperature.
Unit: 0.000001 C(centigrade)
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001 C(centigrade) SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.6 |
| hwXponOntDdmInfoExSupplyVoltage Voltage of the optical transceiver on the ONT.
Unit: 0.000001V
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.7 |
| hwXponOntDdmInfoExSupplyVoltageHighAlarmThreshold Upper alarm threshold of the voltage.
Unit: 0.000001V
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.8 |
| hwXponOntDdmInfoExSupplyVoltageLowAlarmThreshold Lower alarm threshold of the voltage.
Unit: 0.000001V
Options:
1. invalid(0x7FFFFFFF) - Indicates that the query fails or no information is detected | column | 0.000001V SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.158.1.1.1.2.1.9 |