hwEntPotsLoopTestTimeProc
HUAWEI-ENT-VOICE-DIAGNOSE-MIB ·
.1.3.6.1.4.1.2011.5.25.314.2.5
Object
scalar
r/w
Enumeration
Indicates the process method, after the time out of busy.
Context
- MIB
- HUAWEI-ENT-VOICE-DIAGNOSE-MIB
- OID
.1.3.6.1.4.1.2011.5.25.314.2.5- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- hwEntPotsLoopTestTable
- Siblings
- 26
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | noTest |
2 | mandatoryTest |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwEntPotsLoopTestOprType Indicates the operation type | scalar | Enumeration | .1.3.6.1.4.1.2011.5.25.314.2.1 |
| hwEntPotsLoopTestInverseResistance Indicates the test result of inverse resistance. | scalar | Enumeration | .1.3.6.1.4.1.2011.5.25.314.2.10 |
| hwEntPotsLoopTestStatus Indicates the test status. | scalar | Enumeration | .1.3.6.1.4.1.2011.5.25.314.2.11 |
| hwEntPotsLoopTestConclusion Indicates the test conclusion. | scalar | Integer32 | .1.3.6.1.4.1.2011.5.25.314.2.12 |
| hwEntPotsLoopTestACAGnd Indicates the a-ground AC voltage. (Unit: v) | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.314.2.13 |
| hwEntPotsLoopTestACBGnd Indicates the b-ground AC voltage. (Unit: v) | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.314.2.14 |
| hwEntPotsLoopTestACAB Indicates the a-b AC voltage. (Unit: v) | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.314.2.15 |
| hwEntPotsLoopTestDCAGnd Indicates the a-ground DC voltage. (Unit: v) | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.314.2.16 |
| hwEntPotsLoopTestDCBGnd Indicates the b-ground DC voltage. (Unit: v) | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.314.2.17 |
| hwEntPotsLoopTestDCAB Indicates the a-b DC voltage. (Unit: v) | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.314.2.18 |
| hwEntPotsLoopTestRAGnd Indicates the a-ground resistance. (Unit: Om) | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.314.2.19 |
| hwEntPotsLoopTestPort Indicates the test port.
bits 31-24: reserved
bits 23-16: slot index
bits 15-8: subcard index
bits 7-0: port index | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.314.2.2 |
| hwEntPotsLoopTestRBGnd Indicates the b-ground resistance. (Unit: Om) | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.314.2.20 |
| hwEntPotsLoopTestRAB Indicates the a-b resistance. (Unit: Om) | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.314.2.21 |
| hwEntPotsLoopTestCAGnd Indicates the a-ground capacitance. (Unit: uF) | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.314.2.22 |
| hwEntPotsLoopTestCBGnd Indicates the b-ground capacitance. (Unit: uF) | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.314.2.23 |
| hwEntPotsLoopTestCAB Indicates the a-b capacitance. (Unit: uF) | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.314.2.24 |
| hwEntPotsLoopTestLR Indicates the loop resistance. (Unit: Om) | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.314.2.25 |
| hwEntPotsLoopTestRRevPole Indicates the rev pole resistance. (Unit: Om) | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.5.25.314.2.26 |
| hwEntPotsLoopTestMSocket Indicates the MSocket. | scalar | Enumeration | .1.3.6.1.4.1.2011.5.25.314.2.27 |
| hwEntPotsLoopTestBusyFlag Indicates the process method, when the test port is busy. | scalar | Enumeration | .1.3.6.1.4.1.2011.5.25.314.2.3 |
| hwEntPotsLoopTestTimeOut Indicates the time out of busy. (Unit: min)
Default: 30 | scalar | Integer32 | .1.3.6.1.4.1.2011.5.25.314.2.4 |
| hwEntPotsLoopTestVoltage Indicates the test result of voltage. | scalar | Enumeration | .1.3.6.1.4.1.2011.5.25.314.2.6 |
| hwEntPotsLoopTestResistance Indicates the test result of resistance. | scalar | Enumeration | .1.3.6.1.4.1.2011.5.25.314.2.7 |
| hwEntPotsLoopTestCapacitance Indicates the test result of capacitance. | scalar | Enumeration | .1.3.6.1.4.1.2011.5.25.314.2.8 |
| hwEntPotsLoopTestLoopResistance Indicates the test result of loop resistance. | scalar | Enumeration | .1.3.6.1.4.1.2011.5.25.314.2.9 |