hwCollectTableInfo
HUAWEI-BULKSTATISTICS-MIB ·
.1.3.6.1.4.1.2011.6.121.2.3
Object
scalar
r/w
OctetString
Information of the table. This object is used for informing the host of the name of the entry that needs to be collected before the collection is started. If there are multiple entries, a comma is used to separate them. For example, if the NMS has already configured three tables of entries, namely, a|b, a|c, and a|d, this parameter can be set to a|b,a|c before the information collection is started. It indicates that information in a|b and a|c needs to be collected. If you want to collect the information about all tables carrying a certain flag, configure to flag|all (flag is an identifier) and the information about all required tables can be collected. For example, when you have tables a|b, a|c, and a|d (a is an identifier; b, c, and d are table names) and configure a|all, the information about the three tables can be collected. when the value of hwCollectTableInfo is the collection of many table names that are split by commas, you are not allowed to name a single table with all or Flag|all (Flag stands for any letter of an ASCII code from 0x21 to 0x7E); when the value of hwCollectTableInfo is a single table name, you can name the table with all or Flag|all. (Flag stands for any letter of an ASCII code from 0x21 to 0x7E).
Context
- MIB
- HUAWEI-BULKSTATISTICS-MIB
- OID
.1.3.6.1.4.1.2011.6.121.2.3- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- hwCollectOperationSet
- Siblings
- 5
Syntax
OctetString
Values & Constraints
Object Constraints
range: 0-510
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwCollectState Operation status of the information collection.
Options:
1.idle(1) -indicates that the operation is in the idle state.
2.collecting(2) -indicates that the information is b… | scalar | Enumeration | .1.3.6.1.4.1.2011.6.121.2.1 |
| hwCollectOperation Administration operation of the information collection.
Options:
1.begin(1) -indicates that the information collection starts.
2.stop(2) -indicates that the information c… | scalar | Enumeration | .1.3.6.1.4.1.2011.6.121.2.2 |
| hwWaitfetchTimeout Duration (s) after which the Waitfetch state times out. After the expiration,
the Waitfetch status collection automatically stops. | scalar | Integer32 | .1.3.6.1.4.1.2011.6.121.2.4 |
| hwCollectMode Mode of the information collection.
Options:
1.all(1) -indicates that collects data of all tables.
2.incremental(2) -indicates that collects data of tables have chang… | scalar | Enumeration | .1.3.6.1.4.1.2011.6.121.2.5 |
| hwCollectSeq Seq of the information collection. | scalar | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.6.121.2.6 |