hwBTSSAdslSeltTestOperType
HUAWEI-BTEST-MIB ·
.1.3.6.1.4.1.2011.6.21.3.1.1.21.1.1
Object
column
r/w
Enumeration
Selt test operation type. Options: 1. stop(1) - Stop selt test of BTSS 2. start(2) - Start selt test of BTSS 3. invalid(-1) - No operation
Context
- MIB
- HUAWEI-BTEST-MIB
- OID
.1.3.6.1.4.1.2011.6.21.3.1.1.21.1.1- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hwBTSSAdslSeltTestEntry
- Table
- hwBTSSAdslSeltTestTable
- Siblings
- 33
Syntax
Enumeration
Values & Constraints
Enumerated Values
-1 | invalid |
1 | stop |
2 | start |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwBTSSAdslSeltTestParamDwnShnCap Selt test parameter Downstream Shannon Capacity. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.10 |
| hwBTSSAdslSeltTestParamInbandNoise Selt test parameter Inband Noise
512 values that indicate inband noise in dBm/Hz,
covering ADSL, ADSL2, and ADSL2+ bands, from 0 to 2.2 MHz. | column | OctetString | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.11 |
| hwBTSSAdslSeltTestParamTerminResp Selt test parameter Termination Response
180 values that indicate termination response magnitude from 0 to 18 kft. | column | OctetString | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.12 |
| hwBTSSAdslSeltTestParamUpMgnAtRate Selt test parameter Upstream Ratevs. Margin.
This value is a measure of the quality of your upstream data
signal relative to the noise on the line. Hundreds of values that
indic… | column | OctetString | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.13 |
| hwBTSSAdslSeltTestParamDwnMgnAtRate Selt test parameter Downstream Rate vs. Margin.
This value is a measure of the quality of your downstream data
signal relative to the noise on the line. Hundreds… | column | OctetString | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.14 |
| hwBTSSAdslSeltTestParamUpRateAtMgn Selt test parameter Upstream Margin vs. Rate. | column | OctetString | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.15 |
| hwBTSSAdslSeltTestParamDwnRateAtMgn Selt test parameter Downstream Margin vs. Rate. | column | OctetString | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.16 |
| hwBTSSAdslSeltTestParamLoopAttenAtFreq Selt test parameter loop attenuation versus frequency.
Every four bytes constitute the result of a tone.
This information may be plotted with the bit frequency
on the X-axis and t… | column | OctetString | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.17 |
| hwBTSSAdslSeltTestParamUnCalibLineScale The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a
scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.18 |
| hwBTSSAdslSeltTestParamUnCalibEchoRespReal The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a
scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index… | column | OctetString | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.19 |
| hwBTSSAdslSeltTestOperResult Selt test operation result.
Options:
1. normal(1) - Selt test of BTSS is successful
2. fail(2) - Fail in selt test of BTSS
3. abort(3) - Selt test of BTSS aborts | column | Enumeration | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.2 |
| hwBTSSAdslSeltTestParamUnCalibEchoRespImg The uncalibrated echo response, UER(i* UER_G*Df), shall be represented in linear format by a
scale factor and a normalized complex number a(i)+j*b(i), where i is a frequency index… | column | OctetString | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.20 |
| hwBTSSAdslSeltTestParamCalibLineScale The scale factor of calibrated echo response shall be coded as a 16 bit
unsigned integer. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.21 |
| hwBTSSAdslSeltTestParamCalibEchoRespReal The calibrated echo response UER(i* f), shall be represented
in linear format by a scale factor and a normalized complex number a(i)+j*b(i),
where i is the subcarrier index i ran… | column | OctetString | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.22 |
| hwBTSSAdslSeltTestParamCalibEchoRespImg The calibrated echo response UER(i* f), shall be represented
in linear format by a scale factor and a normalized complex number a(i)+j*b(i),
where i is the subcarrier index i ran… | column | OctetString | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.23 |
| hwBTSSAdslSeltTestParamVarUerC The relative variance of the uncalibrated echo response REL_VAR_UER(i* UER_G *Df) shall be
represented as an 8-bit unsigned integer v(i), where i is the subcarrier index i = 0 to … | column | OctetString | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.24 |
| hwBTSSAdslSeltTestParamUerMmdC This parameter is the maximum allowed time for SELT uncalibrated echo response measurement,
between the time of the start command written by the SELT-PMD-ME, and the time the resu… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.25 |
| hwBTSSAdslSeltTestParamQlnMmdC This parameter is the maximum allowed time for SELT quiet line noise measurement, between the
time of the start command written by the SELT-PMD-ME, and the time the result is avai… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.26 |
| hwBTSSAdslSeltTestParamUmeC This parameter is a binary variable.
Options:
1.enable(1) - Enable UER capture switch
2.disable(2) - Disable UER capture switch
3.invalid(-1) - Invalid val… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.27 |
| hwBTSSAdslSeltTestParamQmeC This parameter is a binary variable.
Options:
1.enable(1) - Enable QLN capture switch
2.disable(2) - Disable QLN capture switch
3.invalid(-1) - Invalid val… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.28 |
| hwBTSSAdslSeltTestParamUerStatus UerStatus.
Options:
1.off(1) - The status is off.
2.running(2) - The status is running.
3.completed(3) - The status is completed.
4.failed(4) - … | column | Enumeration | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.29 |
| hwBTSSAdslSeltTestResultNo Selt test result serial number.
Range: 1-255 | column | Integer32 | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.3 |
| hwBTSSAdslSeltTestParamQlnStatus QlnStatus.
Options:
1.off(1) - The status is off.
2.running(2) - The status is running.
3.completed(3) - The status is completed.
4.failed(4) - … | column | Enumeration | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.30 |
| hwBTSSAdslSeltTestParamCalcEnable The status of calculation switch.
Options:
1. enable(1) - Enable calculation switch
2. disable(2) - Disable calculation switch
3. invalid(-1) - Invalid value
Def… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.31 |
| hwBTSSAdslSeltTestResultLastFlag Last package flag of test.
Options:
1. false(0) - This is not the last package
2. true(1) - The last package | column | Enumeration | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.4 |
| hwBTSSAdslSeltTestResult Selt test result data. | column | OctetString | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.5 |
| hwBTSSAdslSeltTestParamLoopLength Selt test parameter Loop Length.
The invalid value is -1. If no SELT is performed, no SELT data is
generated because the SELT is incomplete, or no SELT data can be
obtained fro… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.6 |
| hwBTSSAdslSeltTestParamAttnAt180KHZ Selt test parameter attenuation at 180KHZ.
It ranges from -1100 to 0 units of 0.1dB(physical values
are -110 to 0 dB).
The invalid value is -1. If no SELT is performed, no SELT d… | column | 0.1dB SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.65535 |
| hwBTSSAdslSeltTestParamAttnAt300KHZ Selt test parameter attenuation at 300KHZ.
It ranges from -1100 to 0 units of 0.1dB(physical values
are -110 to 0 dB).
The invalid value is -1. If no SELT is performed, no SELT d… | column | 0.1dB SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.65536 |
| hwBTSSAdslSeltTestParamQSPsdValue The SELT quiet line noise provides the quiet line noise PSD as measured by the SELT-PMD
function (see clause A.1.1.2) for each sub-carrier frequency i * SELTQLN_G * Df where i ran… | column | 0.5dBm/Hz OctetString | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.65537 |
| hwBTSSAdslSeltTestParamLoopTermin Selt test parameter Loop Termination state.
Options:
1. open(0) - Indicates that the line terminal is started
2. short(1) - Indicates that the line terminal is short-ci… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.7 |
| hwBTSSAdslSeltTestParamLoopGauge Selt test parameter Loop Gauge.
Options:
1. greater26awg(1) - Indicates that the line gauge is greater than 26
2. equal26awg(2) - Indicates that the line gauge is 26
3. equal24a… | column | Enumeration | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.8 |
| hwBTSSAdslSeltTestParamUpShnCap Selt test parameter Upstream Shannon Capacity.
The invalid value is -1. If no SELT is performed, no SELT data is
generated because the SELT is incomplete, or no SELT data can be… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2011.6.21.3.1.1.21.1.9 |