hpnicfVoiceIfCfgTimerFirstDial
HPN-ICF-VOICE-IF-MIB ·
.1.3.6.1.4.1.11.2.14.11.15.2.39.13.1.1.1.8
Object
column
r/w
Integer32
The period of time, in seconds, before dialing the first number. The default value of this object is 10 seconds. It is applicable to FXO, FXS subscriber lines and E1/T1 with loop-start or ground-start protocol voice subscriber line.
Context
- MIB
- HPN-ICF-VOICE-IF-MIB
- OID
.1.3.6.1.4.1.11.2.14.11.15.2.39.13.1.1.1.8- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hpnicfVoiceIfConfigEntry
- Table
- hpnicfVoiceIfConfigTable
- Siblings
- 9
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-300
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hpnicfVoiceIfCfgCngOn This object indicates whether the silence gaps should be
filled with background noise. It is applicable to FXO, FXS,
E&M subscriber lines and E1/T1 voice subscriber line. | column | Enumeration | .1.3.6.1.4.1.11.2.14.11.15.2.39.13.1.1.1.1 |
| hpnicfVoiceIfCfgRegTone This object uses 2 or 3 letter country code specify voice
parameters of different countrys. This value will take effect
on all voice interfaces of all cards on the device. | column | OctetString | .1.3.6.1.4.1.11.2.14.11.15.2.39.13.1.1.1.10 |
| hpnicfVoiceIfCfgNonLinearSwitch This object expresses the nonlinear processing is enable
or disable for the voice interface. It is applicable to FXO,
FXS, E&M subscriber lines and E1/T1 voice subscriber line.
Cu… | column | Enumeration | .1.3.6.1.4.1.11.2.14.11.15.2.39.13.1.1.1.2 |
| hpnicfVoiceIfCfgInputGain This object indicates the amount of gain added to the receiver
side of the voice interface. Unit is 0.1 db. It is applicable to
FXO, FXS, E&M subscriber lines and E1/T1 voice subs… | column | Integer32 | .1.3.6.1.4.1.11.2.14.11.15.2.39.13.1.1.1.3 |
| hpnicfVoiceIfCfgOutputGain This object indicates the amount of gain added to the send side
of the voice interface. Unit is 0.1 db. It is applicable to FXO,
FXS, E&M subscriber lines and E1/T1 voice subscrib… | column | Integer32 | .1.3.6.1.4.1.11.2.14.11.15.2.39.13.1.1.1.4 |
| hpnicfVoiceIfCfgEchoCancelSwitch This object indicates whether the echo cancellation is enabled.
It is applicable to FXO, FXS, E&M subscriber lines and E1/T1 voice
subscriber line. | column | Enumeration | .1.3.6.1.4.1.11.2.14.11.15.2.39.13.1.1.1.5 |
| hpnicfVoiceIfCfgEchoCancelDelay This object indicates the delay of the echo cancellation for
the voice interface. This value couldn't be modified unless
hpnicfVoiceIfCfgEchoCancelSwitch is enable. Unit is millis… | column | Integer32 | .1.3.6.1.4.1.11.2.14.11.15.2.39.13.1.1.1.6 |
| hpnicfVoiceIfCfgTimerDialInterval The interval, in seconds, between two dialing numbers.
The default value of this object is 10 seconds. It is
applicable to FXO, FXS, E&M subscriber lines and E1/T1 with
loop-start… | column | Integer32 | .1.3.6.1.4.1.11.2.14.11.15.2.39.13.1.1.1.7 |
| hpnicfVoiceIfCfgPrivateline This object indicates the E.164 phone number for plar mode.
It is applicable to FXO, FXS, E&M subscriber lines and E1/T1
voice subscriber line. | column | OctetString | .1.3.6.1.4.1.11.2.14.11.15.2.39.13.1.1.1.9 |