hpnicfVoiceIfCfgTimerFirstDial

HPN-ICF-VOICE-IF-MIB · .1.3.6.1.4.1.11.2.14.11.15.2.39.13.1.1.1.8

Object

column r/w Integer32
The period of time, in seconds, before dialing the first
number. The default value of this object is 10 seconds. It
is applicable to FXO, FXS subscriber lines and E1/T1 with
loop-start or ground-start protocol voice subscriber line.

Context

MIB
HPN-ICF-VOICE-IF-MIB
OID
.1.3.6.1.4.1.11.2.14.11.15.2.39.13.1.1.1.8
Type
column
Access
readwrite
Status
current
Parent
hpnicfVoiceIfConfigEntry
Table
hpnicfVoiceIfConfigTable
Siblings
9

Syntax

Integer32

Values & Constraints

Object Constraints
range: 1-300

Related Objects

Sibling Objects