hpEMSNormalEvent
HP-EMS ·
.1.3.6.1.4.1.11.2.3.1.7.0.1
Object
notification
The Event Monitoring Service (EMS) has generated an event
for a monitored resource.
A Normal Event occurs when the value of the resource is in
a 'normal' state and the threshold condition is not true.
Monitoring requests configured for initial or return
notification may generate this event. Also, the initial
notification for a Change event is 'normal'.
The data passed with the event:
1) The name of the resource being monitored.
2) The request id, a unique identifier for the
monitoring request. This value should be used when
using resdata to retrieve additional information
about the event.
3) The operator used by EMS to determine when event
notifications should be sent. Possible values
include: poll, change, >, >=, <, <=, = and !=.
4) The resource type, which defines the type of value
being monitored. Possible values include: string,
enumerated, integer, and float.
5) The resource value, which is the current value of the
resource being monitored. It is converted based on
the resource type.
6) The threshold type (usually the same as the resource
type) defines the type of value configured for the
threshold. Possible values include: string,
integer, and float.
7) The threshold value configured for the resource being
monitored.
8) The user data flag, which indicates whether or not
user data are available. User data are comments
provided by the user when the request was configured.
User data can be retrieved on the source node by
running:
/opt/resmon/bin/resdata -r <resource name> \
-R <request id> -u
9) The monitor data flag, which indicates whether or not
the monitor has additional data regarding the event.
Additional data provided by the resource monitor
can be retrieved on the source node by running:
/opt/resmon/bin/resdata -r <resource name> \
-R <request id> [-n <notify id>] -m
10) The notification trigger indicates if the resource
condition is normal or not. For an EMSNormalEvent
trap, the notification trigger is normal.
11) The event type indicates the type of notification
being sent. The different types are:
Poll - for notification at every interval
Change - for notification when the value changes
Normal - for notification when the threshold
condition for the resource is not true
Problem - for notification when the threshold
condition for the resource is true
Error - for notification when the monitor
encountered an error determining
the resource value
12) The notify id, a unique identifier for a specific
notification event. This value should be used when
using resdata to retrieve additional information
about the event. Monitor data can be retrieved
on the source node by running:
/opt/resmon/bin/resdata -r <resource name> \
-R <request id> [-n <notify id>] -m
Context
- MIB
- HP-EMS
- OID
.1.3.6.1.4.1.11.2.3.1.7.0.1- Type
- notification
- Status
- current
- Parent
- hpEMSTraps
- Siblings
- 8
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hpEMSProblemEvent The Event Monitoring Service (EMS) has generated an event
for a monitored resource.
A Problem Event occurs when the threshold condition defined
for the resource is t… | notification | - | .1.3.6.1.4.1.11.2.3.1.7.0.2 |
| hpEMSMonitorReboot The Event Monitoring Service (EMS) has generated an event
for a monitored resource.
A Monitor Reboot Event occurs when monitors are restarted
due to a system reboot.
… | notification | - | .1.3.6.1.4.1.11.2.3.1.7.0.3 |
| hpEMSMonitorRestart The Event Monitoring Service (EMS) has generated an event
for a monitored resource.
A Monitor Restart Event occurs when EMS detects that a
required monitor is no long… | notification | - | .1.3.6.1.4.1.11.2.3.1.7.0.4 |
| hpEMSNormalSevEvent The Event Monitoring Service (EMS) has generated an event
for a monitored resource.
A Problem Event occurs when the threshold condition defined
for the resource is t… | notification | - | .1.3.6.1.4.1.11.2.3.1.7.0.5 |
| hpEMSWarningEvent The Event Monitoring Service (EMS) has generated an event
for a monitored resource.
A Problem Event occurs when the threshold condition defined
for the resource is t… | notification | - | .1.3.6.1.4.1.11.2.3.1.7.0.6 |
| hpEMSMinorEvent The Event Monitoring Service (EMS) has generated an event
for a monitored resource.
A Problem Event occurs when the threshold condition defined
for the resource is t… | notification | - | .1.3.6.1.4.1.11.2.3.1.7.0.7 |
| hpEMSMajorEvent The Event Monitoring Service (EMS) has generated an event
for a monitored resource.
A Problem Event occurs when the threshold condition defined
for the resource is t… | notification | - | .1.3.6.1.4.1.11.2.3.1.7.0.8 |
| hpEMSCriticalEvent The Event Monitoring Service (EMS) has generated an event
for a monitored resource.
A Problem Event occurs when the threshold condition defined
for the resource is t… | notification | - | .1.3.6.1.4.1.11.2.3.1.7.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hpEMSResourceName Full EMS name of the resource being monitored | scalar | OctetString | .1.3.6.1.4.1.11.2.3.1.7.1.1.1 |
| hpEMSRequestID A unique identifier for the monitoring request | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.3.1.7.1.1.2 |
| hpEMSOperator Operator indicates poll, change or threshold condition
operator: >, >=, <, <=, ==, != | scalar | OctetString | .1.3.6.1.4.1.11.2.3.1.7.1.1.3 |
| hpEMSResourceType Integer representing the resource type:
3009 = String
3010 = Sbit32 (signed 32 bit integer)
3011 = Ubit32 (unsigned 32 bit integer)
3012 = Sbit64 (future use)
3013 = Ubit64 (futu… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.3.1.7.1.1.4 |
| hpEMSResourceValue Quoted string representing resource value,
should be converted using the Resource Type
indicated in Variable #4
Not applicable if Resource Type is Error | scalar | OctetString | .1.3.6.1.4.1.11.2.3.1.7.1.1.5 |
| hpEMSThresholdType Integer representing the threshold type,
this is usually the same as resource type.
Integer representing the threshold type:
3009 = String
3010 = Sbit32 (signed 32 bit inte… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.3.1.7.1.1.6 |
| hpEMSThresholdValue Quoted string representing threshold value,
should be converted using the Threshold Type
indicated in Variable #6.
Not applicable if operator is poll or change;
or if Reso… | scalar | OctetString | .1.3.6.1.4.1.11.2.3.1.7.1.1.7 |
| hpEMSUserDataFlag Indicates that additional user data is available from EMS
0 = no user data
1 = user (comment) data exists | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.3.1.7.1.1.8 |
| hpEMSMonitorDataFlag Indicates that additional monitor data is available from EMS
0 = no monitor data
1 = monitor data exists | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.3.1.7.1.1.9 |
| hpEMSNotificationTrigger Indicates whether normal or problem event
0 = normal
1 = abnormal (threshold is true)
5 = abnormal (severity is normal)
6 = abnormal (severity is warning)
7 = abnormal (severity … | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.3.1.7.1.1.10 |
| hpEMSEventType String representing event type:
Poll (for 'At Every Interval')
Change (for 'When value changes')
Normal (for when threshold condition is not true)
Problem (for when thres… | scalar | OctetString | .1.3.6.1.4.1.11.2.3.1.7.1.1.11 |
| hpEMSNotifyID Unique identifier for this particular event | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.11.2.3.1.7.1.1.12 |