hm2DiagCableTesterCableStatus

HM2-DIAGNOSTIC-MIB · .1.3.6.1.4.1.248.11.22.1.6.10.1.2

Object

column Enumeration
Indicates the results of the Cable Test.
normal(1)        - The cable is working correctly.
open(2)          - The cable is disconnected or there is a faulty
                   connector.
short(3)         - There is an electrical short in the cable.
unknown(4)       - No test has been performed yet, or a test is
                   currently in progress.

Context

MIB
HM2-DIAGNOSTIC-MIB
OID
.1.3.6.1.4.1.248.11.22.1.6.10.1.2
Type
column
Access
readonly
Status
current
Parent
hm2DiagCableTesterCableEntry
Table
hm2DiagCableTesterCableTable
Siblings
4

Syntax

Enumeration

Values & Constraints

Enumerated Values
1normal
2open
3short
4unknown