hmAgentStpCstBridgeHoldCount

HIRSCHMANN-MMP4-BASICL2-MIB · .1.3.6.1.4.1.248.15.1.2.15.8.17

Object

scalar r/w Unsigned32
The MSTP bridge hold count for the CIST. This command sets the value of
maximum bpdus that a bridge is allowed to send within a hello time window.
The default value is 10.

Context

MIB
HIRSCHMANN-MMP4-BASICL2-MIB
OID
.1.3.6.1.4.1.248.15.1.2.15.8.17
Type
scalar
Access
readwrite
Status
current
Parent
hmAgentStpCstConfigGroup
Siblings
16

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 1-40

Related Objects

Sibling Objects