hh3cTransceiverActiveITUChannel
HH3C-TRANSCEIVER-INFO-MIB ·
.1.3.6.1.4.1.25506.2.70.1.1.1.42
Object
column
r/w
Unsigned32
The index of the current ITU channel on the connected transceiver. The maximum index number for the ITU channel might vary by transceiver model. The value of this node depends on the hh3cTransceiverITUChanIdx node of hh3cTransceiverITUChanTable. The value of this node affects the frequency or wavelength.
Context
- MIB
- HH3C-TRANSCEIVER-INFO-MIB
- OID
.1.3.6.1.4.1.25506.2.70.1.1.1.42- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hh3cTransceiverInfoEntry
- Table
- hh3cTransceiverInfoTable
- Siblings
- 64
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 1-4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hh3cTransceiverHardwareType Hardware type of the interface, such as SM(single mode). | column | OctetString | .1.3.6.1.4.1.25506.2.70.1.1.1.1 |
| hh3cTransceiverMaxTXPower Indicating the maximum transmitted power.
The unit is in hundredths of dBm. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.10 |
| hh3cTransceiverMinTXPower Indicating the minimum transmitted power.
The unit is in hundredths of dBm. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.11 |
| hh3cTransceiverCurRXPower Indicating the current received power.
The unit is in hundredths of dBm. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.12 |
| hh3cTransceiverMaxRXPower Indicating the maximum received power.
The unit is in hundredths of dBm. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.13 |
| hh3cTransceiverMinRXPower Indicating the minimum received power.
The unit is in hundredths of dBm. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.14 |
| hh3cTransceiverTemperature Indicating the current temperature.
The unit is Celsius centigrade. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.15 |
| hh3cTransceiverVoltage Indicating the current voltage.
The unit is in hundredths of V | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.16 |
| hh3cTransceiverBiasCurrent Indicating the current bias electric current.
The unit is in hundredths of mA | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.17 |
| hh3cTransceiverTempHiAlarm Transceiver temperature high alarm threshold
in thousandths of degrees Celsius.
As an example: 49120 is 49.120 degrees Celsius. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.18 |
| hh3cTransceiverTempLoAlarm Transceiver temperature low alarm threshold
in thousandths of degrees Celsius.
As an example: 49120 is 49.120 degrees Celsius. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.19 |
| hh3cTransceiverType Type of the interface, such as SFP/XFP/GBIC. | column | OctetString | .1.3.6.1.4.1.25506.2.70.1.1.1.2 |
| hh3cTransceiverTempHiWarn Transceiver temperature high warning threshold
in thousandths of degrees Celsius.
As an example: 49120 is 49.120 degrees Celsius. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.20 |
| hh3cTransceiverTempLoWarn Transceiver temperature low warning threshold
in thousandths of degrees Celsius.
As an example: 49120 is 49.120 degrees Celsius. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.21 |
| hh3cTransceiverVccHiAlarm Transceiver VCC high alarm threshold
in hundreds of microvolts.
As an example: 32928 is 3.2928 volts.
Returns zero if not supported on the transceiver. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.22 |
| hh3cTransceiverVccLoAlarm Transceiver VCC low alarm threshold
in hundreds of microvolts.
As an example: 32928 is 3.2928 volts.
Returns zero if not supported on the transceiver. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.23 |
| hh3cTransceiverVccHiWarn Transceiver VCC high warning threshold
in hundreds of microvolts.
As an example: 32928 is 3.2928 volts.
Returns zero if not supported on the transceiver. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.24 |
| hh3cTransceiverVccLoWarn Transceiver VCC low warning threshold
in hundreds of microvolts.
As an example: 32928 is 3.2928 volts.
Returns zero if not supported on the transceiver. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.25 |
| hh3cTransceiverBiasHiAlarm Transceiver bias high alarm threshold in microamps. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.26 |
| hh3cTransceiverBiasLoAlarm Transceiver bias low alarm threshold in microamps. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.27 |
| hh3cTransceiverBiasHiWarn Transceiver bias high warning threshold in microamps. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.28 |
| hh3cTransceiverBiasLoWarn Transceiver bias low warning threshold in microamps. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.29 |
| hh3cTransceiverWaveLength Wave length of the interface, measured in nanometer.
The unit is nm. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.3 |
| hh3cTransceiverPwrOutHiAlarm Transceiver transmit power high alarm
threshold in tenths of microwatts.
As an example: 10000 is 1 milliwatt. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.30 |
| hh3cTransceiverPwrOutLoAlarm Transceiver transmit power low alarm
threshold in tenths of microwatts.
As an example: 10000 is 1 milliwatt. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.31 |
| hh3cTransceiverPwrOutHiWarn Transceiver transmit power high warning
threshold in tenths of microwatts
As an example: 10000 is 1 milliwatt. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.32 |
| hh3cTransceiverPwrOutLoWarn Transceiver transmit power low warning
threshold in tenths of microwatts.
As an example: 10000 is 1 milliwatt. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.33 |
| hh3cTransceiverRcvPwrHiAlarm Transceiver receive power high alarm
threshold in tenths of microwatts.
As an example: 10000 is 1 milliwatt. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.34 |
| hh3cTransceiverRcvPwrLoAlarm Transceiver receive power low alarm
threshold in tenths of microwatts.
As an example: 10000 is 1 milliwatt. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.35 |
| hh3cTransceiverRcvPwrHiWarn Transceiver receive power high warning
threshold in tenths of microwatts.
As an example: 10000 is 1 milliwatt. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.36 |
| hh3cTransceiverRcvPwrLoWarn Transceiver receive power low warning
threshold in tenths of microwatts.
As an example: 10000 is 1 milliwatt. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.37 |
| hh3cTransceiverErrors Bitmask indicating transceiver errors.
Transceiver information I/O error(0)
Transceiver information checksum error(1)
Transceiver type and port configuration mismatch(2)
Transceiv… | column | Bits | .1.3.6.1.4.1.25506.2.70.1.1.1.38 |
| hh3cTransceiverVendorOUI Vendor OUI of the interface. | column | OctetString | .1.3.6.1.4.1.25506.2.70.1.1.1.39 |
| hh3cTransceiverVendorName Vendor name of the interface. | column | OctetString | .1.3.6.1.4.1.25506.2.70.1.1.1.4 |
| hh3cTransceiverRevisionNumber Revision number of the interface. | column | OctetString | .1.3.6.1.4.1.25506.2.70.1.1.1.40 |
| hh3cTransceiverFrequency The frequency of the current ITU channel on the connected transceiver.
The unit is hundredths of THz. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.41 |
| hh3cTransceiverCurWaveErr The current wavelength error of the current ITU channel
on the connected transceiver.
The unit is thousandths of nm. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.43 |
| hh3cTransceiverWaveErrHiAlarm The high wavelength error alarm threshold of the
current ITU channel on the connected transceiver.
The unit is thousandths of nm. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.44 |
| hh3cTransceiverWaveErrLoAlarm The low wavelength error alarm threshold of the
current ITU channel on the connected transceiver.
The unit is thousandths of nm. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.45 |
| hh3cTransceiverCurFreqErr The current frequency error of the current ITU channel
on the connected transceiver.
The unit is tenths of GHz. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.46 |
| hh3cTransceiverFreqErrHiAlarm The high frequency error alarm threshold of the current
ITU channel on the connected transceiver.
The unit is tenths of GHz. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.47 |
| hh3cTransceiverFreqErrLoAlarm The low frequency error alarm threshold of the current
ITU channel on the connected transceiver.
The unit is tenths of GHz. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.48 |
| hh3cTransceiverPartNumber PartNumber of the interface.
As an example: 1110409083. | column | OctetString | .1.3.6.1.4.1.25506.2.70.1.1.1.49 |
| hh3cTransceiverSerialNumber Serial number of the interface. | column | OctetString | .1.3.6.1.4.1.25506.2.70.1.1.1.5 |
| hh3cTransceiverProductCode Product Code of the interface.
As an example: MRC00CD. | column | OctetString | .1.3.6.1.4.1.25506.2.70.1.1.1.50 |
| hh3cTransceiverOriginalSN Orginal serial number of the interface. | column | OctetString | .1.3.6.1.4.1.25506.2.70.1.1.1.51 |
| hh3cTransceiverPwrOutHiAlarmDbm Transceiver transmit power high alarm
threshold in hundredths of dBm.
As an example: 100 milliwatts is 20 dBms. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.52 |
| hh3cTransceiverPwrOutLoAlarmDbm Transceiver transmit power low alarm
threshold in hundredths of dBm.
As an example: 100 milliwatts is 20 dBms. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.53 |
| hh3cTransceiverPwrOutHiWarnDbm Transceiver transmit power high warning
threshold in hundredths of dBm.
As an example: 100 milliwatts is 20 dBms. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.54 |
| hh3cTransceiverPwrOutLoWarnDbm Transceiver transmit power low warning
threshold in hundredths of dBm.
As an example: 100 milliwatts is 20 dBms. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.55 |
| hh3cTransceiverRcvPwrHiAlarmDbm Transceiver receive power high alarm
threshold in hundredths of dBm.
As an example: 100 milliwatts is 20 dBms. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.56 |
| hh3cTransceiverRcvPwrLoAlarmDbm Transceiver receive power low alarm
threshold in hundredths of dBm.
As an example: 100 milliwatts is 20 dBms. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.57 |
| hh3cTransceiverRcvPwrHiWarnDbm Transceiver receive power high warning
threshold in hundredths of dBm.
As an example: 100 milliwatts is 20 dBms. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.58 |
| hh3cTransceiverRcvPwrLoWarnDbm Transceiver receive power low warning
threshold in hundredths of dBm.
As an example: 100 milliwatts is 20 dBms. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.59 |
| hh3cTransceiverFiberDiameterType The diameter of the fiber, measured in micron.
fiber9 - 9 micron multi-mode fiber
fiber50 - 50 micron multi-mode fiber
fiber625 - 62.5 micron multi-mode fiber
copper - copper cabl… | column | Enumeration | .1.3.6.1.4.1.25506.2.70.1.1.1.6 |
| hh3cTransceiverRelySlotMfgName Vendor name of the card on which the transceiver is installed. | column | OctetString | .1.3.6.1.4.1.25506.2.70.1.1.1.60 |
| hh3cTransceiverRelySlotMfgDate Manufacturing date of the card on which the transceiver is installed. | column | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.25506.2.70.1.1.1.61 |
| hh3cTransceiverCurrentPower Current transceiver real-time power.
The unit is thousandths of w. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.62 |
| hh3cTransceiverMaxPower Current transceiver maximum power.
The unit is thousandths of w. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.63 |
| hh3cTransceiverTotalTXPower Indicating the total transmitted power.
The unit is in hundredths of dBm. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.64 |
| hh3cTransceiverTotalRXPower Indicating the total received power.
The unit is in hundredths of dBm. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.65 |
| hh3cTransceiverTransferDistance The maximum distance which the interface can transmit,
measured in meter. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.7 |
| hh3cTransceiverDiagnostic Indicating the digital diagnostic monitoring function. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.25506.2.70.1.1.1.8 |
| hh3cTransceiverCurTXPower Indicating the current transmitted power.
The unit is in hundredths of dBm. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.25506.2.70.1.1.1.9 |