hh3cRaidHideStateNotification
HH3C-STORAGE-MIB ·
.1.3.6.1.4.1.25506.10.1.1.3.0.13
Object
notification
The hh3cRaidFailedNotification indicates that a array hide or unhide.
Context
- MIB
- HH3C-STORAGE-MIB
- OID
.1.3.6.1.4.1.25506.10.1.1.3.0.13- Type
- notification
- Status
- current
- Parent
- hh3cStorageTrapsPrefix
- Siblings
- 27
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hh3cStorCriticalLowerTemperatureThresholdNotification The hh3cStorCriticalLowerTemperatureThresholdNotification indicates
the temperature is lower than the threshold.
If the temperature is lower too much than the entity ne… | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.1 |
| hh3cDiskIOErrorNotification The hh3cDiskIOErrorNotification indicates that a disk occurred I/O error. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.10 |
| hh3cRaidCreateNotification The hh3cRaidCreateNotification indicates that a array is created. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.11 |
| hh3cRaidDeleteNotification The hh3cRaidDeleteStateNotification indicates that a array is deleted. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.12 |
| hh3cRaidRunStateNotification The hh3cRaidDegradeNotification indicates that a array state change. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.14 |
| hh3cRaidImportNotification The hh3cRaidFailedNotification indicates that a thrid array is imported. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.15 |
| hh3cRaidRebuildStartNotification The hh3cRaidRebuildStartNotification indicates that
a array start to rebuild. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.16 |
| hh3cRaidRebuildFinishNotification The hh3cRaidRebuildStartNotification indicates that
a array fininsh rebuild. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.17 |
| hh3cRaidRebuildPauseNotification The hh3cRaidRebuildPauseNotification indicates that
pause a array rebuilding. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.18 |
| hh3cRaidRebuildInterruptNotification The hh3cRaidRebuildInterruptNotification indicates that
interrupt a array rebuilding. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.19 |
| hh3cStorTemperatureTooLow The hh3cStorTemperatureTooLow indicates the temperature is
lower than the threshold.
If the temperature is lower too much than the entity needs,
the entity halts now. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.2 |
| hh3cSoftwareModuleFailNotification The hh3cSoftwareModuleFailNotification indicates that software module(s) fail. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.20 |
| hh3cRaidBatteryExpiredNotification The hh3cRaidBatteryExpiredNotification indicates
RAID Battery lifetime had expired. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.21 |
| hh3cRaidBatteryWillExpireNotification The hh3cRaidBatteryWillExpireNotification indicates
RAID Battery lifetime will expire. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.22 |
| hh3cLvOnlineFailNotification The hh3cLvOnlineFailNotification indicates lv(s) on vd fail to online. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.23 |
| hh3cLvOfflineFailNotification The hh3cLvOfflineFailNotification indicates lv(s) on vd fail to offline. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.24 |
| hh3cRaidRunNotification The hh3cRaidRunNotification indicates that a array is running. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.25 |
| hh3cExtVoltageNormal The hh3cStorVoltageRecoveryNotification indicates
the Voltage has recovered in reference. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.26 |
| hh3cDiskPowerOnNotification The hh3cDiskPowerOnNotification indicates that
a disk is power on. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.27 |
| hh3cDiskPowerOffNotification The hh3cDiskPowerOffNotification indicates that
a disk is power off. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.28 |
| hh3cExtVoltageLowThresholdNotification The hh3cExtVoltageLowThresholdNotification indicates
the Voltage is lower than the low-threshold. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.3 |
| hh3cExtVoltageHighThresholdNotification The hh3cExtVoltageHighThresholdNotification indicates
the Voltage is lower than the high-threshold. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.4 |
| hh3cExtCriticalVoltageLowThresholdNotification The hh3cExtCriticalVoltageLowThresholdNotification indicates
the Voltage is lower than the critical low threshold. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.5 |
| hh3cExtCriticalVoltageHighThresholdNotification The hh3cExtCriticalVoltageHighThresholdNotification indicates
the Voltage is higher than the critical high threshold. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.6 |
| hh3cExtVoltageTooLow The hh3cExtVoltageTooLowNotification indicates
the Voltage is lower than the critical low threshold,
and the entity halt now! | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.7 |
| hh3cExtVoltageTooHigh The hh3cExtVoltageTooHighNotification indicates
the Voltage is higher than the critical high threshold,
and the entity halt now! | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.8 |
| hh3cExtBatteryStateNotification The hh3cExtBatteryStateNotification indicates
the raid battery entity's state changes. | notification | - | .1.3.6.1.4.1.25506.10.1.1.3.0.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| HH3C-RAID-MIBhh3cRaidUuid This object describes the UUID of the array. | column | HH3C-STORAGE-REF-MIBHh3cRaidIDType | .1.3.6.1.4.1.25506.10.4.1.2.1.3 |
| HH3C-RAID-MIBhh3cRaidName This object identifies the name of the array. | column | OctetString | .1.3.6.1.4.1.25506.10.4.1.2.1.1 |
| HH3C-RAID-MIBhh3cRaidHideState This object identifies if the array is hided. When the value of
this object is equal to 'enable', the array will be hided and the
files on it can not be accessed by any user. | column | HH3C-STORAGE-REF-MIBHh3cStorageEnableState | .1.3.6.1.4.1.25506.10.4.1.3.1.6 |