sc10Name
GEIST-MIB-V3 ·
.1.3.6.1.4.1.21239.2.35.1.3
Object
column
SNMPv2-TCDisplayString
Friendly Name
Context
- MIB
- GEIST-MIB-V3
- OID
.1.3.6.1.4.1.21239.2.35.1.3- Type
- column
- Access
- readonly
- Status
- current
- Parent
- sc10Entry
- Table
- sc10Table
- Siblings
- 9
Values & Constraints
Type Constraints
range: 0..255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sc10Index Table entry index value | column | Integer32 | .1.3.6.1.4.1.21239.2.35.1.1 |
| sc10Capacity Current capacity for Fan Speed | column | % Integer32 | .1.3.6.1.4.1.21239.2.35.1.10 |
| sc10Serial Serial Number | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21239.2.35.1.2 |
| sc10Avail Is device currently plugged in? | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.35.1.4 |
| sc10ControlMode Control Mode setting indicator | column | Enumeration | .1.3.6.1.4.1.21239.2.35.1.5 |
| sc10SetpointC Current temperature set point in C | column | Degrees Celsius Integer32 | .1.3.6.1.4.1.21239.2.35.1.6 |
| sc10SetpointF Current temperature set point in F | column | Degrees Fahrenheit Integer32 | .1.3.6.1.4.1.21239.2.35.1.7 |
| sc10TempC Current internal temperature reading in C | column | Degrees Celsius Integer32 | .1.3.6.1.4.1.21239.2.35.1.8 |
| sc10TempF Current internal temperature reading in F | column | Degrees Fahrenheit Integer32 | .1.3.6.1.4.1.21239.2.35.1.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| airFlowSensorDewPointC Current reading for Dew Point (C) | column | Degrees Celsius Integer32 | .1.3.6.1.4.1.21239.2.5.1.9 |
| airFlowSensorName Friendly Name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21239.2.5.1.3 |
| productFriendlyName User-assigned name | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21239.2.1.3 |
| alarmTripType Type of alarm trip. 0 = None, 1 = Low, 2 = High, 3 = Unplugged | scalar | Enumeration | .1.3.6.1.4.1.21239.2.1.6 |
| temperaturePrecision Temperature Precision:
0 = degree: whole degree (value X 1)
1 = deci-degree: tenths of a degree (value X 10)
ex. 550 = 55.0 degrees | scalar | Enumeration | .1.3.6.1.4.1.21239.2.1.9 |
| alarmTrigger Used in a trap var-bind to indicate what triggered
the alarm. The alarmTrigger will remain consistent
for both trip and clear traps. Possible values include:
'Low… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21239.2.1.11 |
| alarmInstance Provides the row index (instance number) for the alarm
that generated a trap. This value is only available when
included in the var-binds of an associated trap. | scalar | Integer32 | .1.3.6.1.4.1.21239.2.1.12 |