ctrlOutletEntry
GEIST-MIB-V3 ·
.1.3.6.1.4.1.21239.2.16.1
Object
row
Entry in the control outlet table: each entry contains an index (ctrlOutletIndex) and other sensor details
Context
- MIB
- GEIST-MIB-V3
- OID
.1.3.6.1.4.1.21239.2.16.1- Type
- row
- Status
- current
- Parent
- ctrlOutletTable
- Table
- ctrlOutletTable
- Children
- 17
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ctrlOutletIndex Outlet Number | column | Integer32 | .1.3.6.1.4.1.21239.2.16.1.1 |
| ctrlOutletRbtDuration Outlet Reboot Duration | column | seconds SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.16.1.10 |
| ctrlOutletURL Outlet URL | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21239.2.16.1.11 |
| ctrlOutletPOAAction POA Action: 1 = Off, 2 = On, 3 = Last, 0 = POA not supported on this unit type | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.16.1.12 |
| ctrlOutletPOADelay POA Delay | column | seconds SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.16.1.13 |
| ctrlOutletkWattHrs Current Reading for kWatt-Hours | column | kWh SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.16.1.14 |
| ctrlOutletPower Current reading for Power | column | Watts SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.16.1.15 |
| ctrlOutletRbtDelay Outlet Reboot Delay | column | seconds SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.16.1.16 |
| ctrlOutletStatusTime Seconds Since Outlet Last Changed Its Status | column | seconds SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.16.1.17 |
| ctrlOutletName Outlet Friendly Name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21239.2.16.1.2 |
| ctrlOutletStatus Current Outlet Status: 0 = Off, 1 = On | Outlet Action Write: 0 = Cancel Pending, 1 = On, 2 = On Delayed, 3 = Off Immediate, 4 = Off Delayed, 5 = Reboot, 6 = Reboot Delayed, 7 = C… | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.16.1.3 |
| ctrlOutletFeedback Outlet Feedback Value, should be equal to status | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.16.1.4 |
| ctrlOutletPending Outlet Status Read to change to: 0 = Off, 1 = On | Outlet Action Write: 0 = Cancel Pending, 1 = On, 2 = On Delayed, 3 = Off Immediate, 4 = Off Delayed, 5 = Reboot, 6 = Reboot Dela… | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.16.1.5 |
| ctrlOutletDeciAmps Outlet DeciAmps reading | column | 0.1 Amps (rms) SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.16.1.6 |
| ctrlOutletGroup Outlet Group (A to G) | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21239.2.16.1.7 |
| ctrlOutletUpDelay Outlet Power Up Delay | column | seconds SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.16.1.8 |
| ctrlOutletDwnDelay Outlet Power Down Delay | column | seconds SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.16.1.9 |