ctrl2CirTotRealPowerTot
GEIST-MIB-V3 ·
.1.3.6.1.4.1.21239.2.34.1.10
Object
Current reading for Real Power (Total)
Context
- MIB
- GEIST-MIB-V3
- OID
.1.3.6.1.4.1.21239.2.34.1.10- Type
- column
- Access
- readonly
- Status
- current
- Units
- Watts
- Parent
- ctrl2CirTotEntry
- Table
- ctrl2CirTotTable
- Siblings
- 27
Syntax
Watts SNMPv2-SMIGauge32
- Source
- SNMPv2-SMIGauge32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ctrl2CirTotIndex Table entry index value | column | Integer32 | .1.3.6.1.4.1.21239.2.34.1.1 |
| ctrl2CirTotApparentPowerTot Current reading for Apparent Power (Total) | column | Volt-Amps SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.11 |
| ctrl2CirTotPowerFactorTot Current reading for Power Factor (Total) | column | % Integer32 | .1.3.6.1.4.1.21239.2.34.1.12 |
| ctrl2CirTotkWattHrsA Current Reading for kWatt-Hours (Phase A) | column | kWh SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.13 |
| ctrl2CirTotVoltsA Current reading for Volts (Phase A) | column | Volts (rms) SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.14 |
| ctrl2CirTotVoltPeakA Current reading for Peak-Volts (Phase A) | column | Volts (rms) SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.15 |
| ctrl2CirTotDeciAmpsA Current reading for DeciAmps (Phase A) | column | 0.1 Amps (rms) SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.16 |
| ctrl2CirTotDeciAmpsPeakA Current reading for Peak-DeciAmps (Phase A) | column | 0.1 Amps (rms) SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.17 |
| ctrl2CirTotRealPowerA Current reading for Real Power (Phase A) | column | Watts SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.18 |
| ctrl2CirTotApparentPowerA Current reading for Apparent Power (Phase A) | column | Volt-Amps SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.19 |
| ctrl2CirTotSerial Serial Number | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21239.2.34.1.2 |
| ctrl2CirTotPowerFactorA Current reading for Power Factor (Phase A) | column | % Integer32 | .1.3.6.1.4.1.21239.2.34.1.20 |
| ctrl2CirTotkWattHrsB Current Reading for kWatt-Hours (Phase B) | column | kWh SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.21 |
| ctrl2CirTotVoltsB Current reading for Volts (Phase B) | column | Volts (rms) SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.22 |
| ctrl2CirTotVoltPeakB Current reading for Peak-Volts (Phase B) | column | Volts (rms) SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.23 |
| ctrl2CirTotDeciAmpsB Current reading for DeciAmps (Phase B) | column | 0.1 Amps (rms) SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.24 |
| ctrl2CirTotDeciAmpsPeakB Current reading for Peak-DeciAmps (Phase B) | column | 0.1 Amps (rms) SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.25 |
| ctrl2CirTotRealPowerB Current reading for Real Power (Phase B) | column | Watts SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.26 |
| ctrl2CirTotApparentPowerB Current reading for Apparent Power (Phase B) | column | Volt-Amps SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.27 |
| ctrl2CirTotPowerFactorB Current reading for Power Factor (Phase B) | column | % Integer32 | .1.3.6.1.4.1.21239.2.34.1.28 |
| ctrl2CirTotName Friendly Name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21239.2.34.1.3 |
| ctrl2CirTotAvail Is device currently plugged in? | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.4 |
| ctrl2CirTotkWattHrsTot Current Reading for kWatt-Hours (Total) | column | kWh SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.5 |
| ctrl2CirTotVoltsTot Current reading for Volts (Total) | column | Volts (rms) SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.6 |
| ctrl2CirTotVoltPeakTot Current reading for Peak-Volts (Total) | column | Volts (rms) SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.7 |
| ctrl2CirTotDeciAmpsTot Current reading for DeciAmps (Total) | column | 0.1 Amps (rms) SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.8 |
| ctrl2CirTotDeciAmpsPeakTot Current reading for Peak-DeciAmps (Total) | column | 0.1 Amps (rms) SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.34.1.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| climateApparentPowerC Current reading for Apparent Power (Phase C) | column | Volt-Amps SNMPv2-SMIGauge32 | .1.3.6.1.4.1.21239.2.2.1.29 |
| climateName Friendly Name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21239.2.2.1.3 |
| productFriendlyName User-assigned name | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21239.2.1.3 |
| alarmTripType Type of alarm trip. 0 = None, 1 = Low, 2 = High, 3 = Unplugged | scalar | Enumeration | .1.3.6.1.4.1.21239.2.1.6 |
| alarmTrigger Used in a trap var-bind to indicate what triggered
the alarm. The alarmTrigger will remain consistent
for both trip and clear traps. Possible values include:
'Low… | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.21239.2.1.11 |
| alarmInstance Provides the row index (instance number) for the alarm
that generated a trap. This value is only available when
included in the var-binds of an associated trap. | scalar | Integer32 | .1.3.6.1.4.1.21239.2.1.12 |