thresholdIntrusionGradient

FspR7-MIB · .1.3.6.1.4.1.2544.1.11.2.6.1.15.1.1

Object

column r/w 0.1 dB/min Unsigned32
Attenuation Gradient Threshold on Receive Fiber. Applies to both
TRMT and RCV directions; but threshold violation is reported for
each direction separately by the 'tapping' alarms: INTRUDE-RCV
and INTRUDE-TRMT.

Context

MIB
FspR7-MIB
OID
.1.3.6.1.4.1.2544.1.11.2.6.1.15.1.1
Type
column
Access
readwrite
Status
current
Units
0.1 dB/min
Parent
thresholdIntrusionEntry
Table
thresholdIntrusionTable

Syntax

0.1 dB/min Unsigned32

Values & Constraints

Object Constraints
range: 5-30 range: 4294967295-4294967295