forceDeployProvApsCapHoldOffTime
FspR7-MIB ·
.1.3.6.1.4.1.2544.1.11.2.5.7.4.1.4
Object
column
ADVA-MIBApsHoldoffTimeCaps
This value controls the switch delay (0 to 10 seconds in 100ms steps) for the protection group. Changing the hold-off time when the timer is active will not affect the active timer. The change will take effect the next time the timer is active.
Context
- MIB
- FspR7-MIB
- OID
.1.3.6.1.4.1.2544.1.11.2.5.7.4.1.4- Type
- column
- Access
- readonly
- Status
- current
- Parent
- forceDeployProvApsCapEntry
- Table
- forceDeployProvApsCapTable
- Siblings
- 14
Values & Constraints
Type Values
0 | capUndefined |
1 | capNone |
2 | capE20ms |
3 | capE100ms |
4 | capE200ms |
5 | capE300ms |
6 | capE400ms |
7 | capE500ms |
8 | capE600ms |
9 | capE700ms |
10 | capE800ms |
11 | capE900ms |
12 | capE1000ms |
13 | capE1100ms |
14 | capE1200ms |
15 | capE1300ms |
16 | capE1400ms |
17 | capE1500ms |
18 | capE1600ms |
19 | capE1700ms |
20 | capE1800ms |
21 | capE1900ms |
22 | capE2000ms |
23 | capE2100ms |
24 | capE2200ms |
25 | capE2300ms |
26 | capE2400ms |
27 | capE2500ms |
28 | capE2600ms |
29 | capE2700ms |
30 | capE2800ms |
31 | capE2900ms |
32 | capE3000ms |
33 | capE3100ms |
34 | capE3200ms |
35 | capE3300ms |
36 | capE3400ms |
37 | capE3500ms |
38 | capE3600ms |
39 | capE3700ms |
40 | capE3800ms |
41 | capE3900ms |
42 | capE4000ms |
43 | capE4100ms |
44 | capE4200ms |
45 | capE4300ms |
46 | capE4400ms |
47 | capE4500ms |
48 | capE4600ms |
49 | capE4700ms |
50 | capE4800ms |
51 | capE4900ms |
52 | capE5000ms |
53 | capE5100ms |
54 | capE5200ms |
55 | capE5300ms |
56 | capE5400ms |
57 | capE5500ms |
58 | capE5600ms |
59 | capE5700ms |
60 | capE5800ms |
61 | capE5900ms |
62 | capE6000ms |
63 | capE6100ms |
64 | capE6200ms |
65 | capE6300ms |
66 | capE6400ms |
67 | capE6500ms |
68 | capE6600ms |
69 | capE6700ms |
70 | capE6800ms |
71 | capE6900ms |
72 | capE7000ms |
73 | capE7100ms |
74 | capE7200ms |
75 | capE7300ms |
76 | capE7400ms |
77 | capE7500ms |
78 | capE7600ms |
79 | capE7700ms |
80 | capE7800ms |
81 | capE7900ms |
82 | capE8000ms |
83 | capE8100ms |
84 | capE8200ms |
85 | capE8300ms |
86 | capE8400ms |
87 | capE8500ms |
88 | capE8600ms |
89 | capE8700ms |
90 | capE8800ms |
91 | capE8900ms |
92 | capE9000ms |
93 | capE9100ms |
94 | capE9200ms |
95 | capE9300ms |
96 | capE9400ms |
97 | capE9500ms |
98 | capE9600ms |
99 | capE9700ms |
100 | capE9800ms |
101 | capE9900ms |
102 | capE10000ms |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| forceDeployProvApsCapRowStatus RowStatus | column | FspR7RowStatusCaps | .1.3.6.1.4.1.2544.1.11.2.5.7.4.1.1 |
| forceDeployProvApsCapFarEndIp IP Address assigned to PPP Termination Point on Far-End NE. Default
is set by NE System on LINK establishment if FENDIPACPT = Y | column | FspR7YesNo | .1.3.6.1.4.1.2544.1.11.2.5.7.4.1.10 |
| forceDeployProvApsCapPeerAid AID of Protection Partner involved in the protection group. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2544.1.11.2.5.7.4.1.11 |
| forceDeployProvApsCapApsType The type of APS implemented in this protection group. | column | ApsTypeCaps | .1.3.6.1.4.1.2544.1.11.2.5.7.4.1.12 |
| forceDeployProvApsCapRevertMode Revertive Protection Switching | column | ApsRevertModeCaps | .1.3.6.1.4.1.2544.1.11.2.5.7.4.1.13 |
| forceDeployProvApsCapWaitToRestore Wait to Restore | column | min FspR7Unsigned32Caps | .1.3.6.1.4.1.2544.1.11.2.5.7.4.1.14 |
| forceDeployProvApsCapDirection Indicates whether the APS function is 'unidirectional' (single-ended)
or 'bidirectional' (dual-ended). | column | ApsDirectionCaps | .1.3.6.1.4.1.2544.1.11.2.5.7.4.1.15 |
| forceDeployProvApsCapForceDestroy Forced Destroy | column | FspR7ForcedStatusCaps | .1.3.6.1.4.1.2544.1.11.2.5.7.4.1.2 |
| forceDeployProvApsCapSDswitching This state controls whether the switch criteria for the APS group will
include the Signal Degrade alarm. | column | ADVA-MIBEnableStateCaps | .1.3.6.1.4.1.2544.1.11.2.5.7.4.1.3 |
| forceDeployProvApsCapProtectionMech The protection type of this protection group. | column | ADVA-MIBProtectionMechCaps | .1.3.6.1.4.1.2544.1.11.2.5.7.4.1.5 |
| forceDeployProvApsCapWorkingAid AID of working port involved in the protection group. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2544.1.11.2.5.7.4.1.6 |
| forceDeployProvApsCapProtectionAid AID of protection entity involved in the protection group. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2544.1.11.2.5.7.4.1.7 |
| forceDeployProvApsCapSignalDegradeSwitching Switch Trigger Additionally on Signal Degrade Link Detection | column | ADVA-MIBEnableStateCaps | .1.3.6.1.4.1.2544.1.11.2.5.7.4.1.8 |
| forceDeployProvApsCapSignalFailureSwitching Switch Trigger on Signal Failure Link Detection | column | ADVA-MIBEnableStateCaps | .1.3.6.1.4.1.2544.1.11.2.5.7.4.1.9 |