flowProtectionStatusApsType
FspR7-LAYER2-MIB ·
.1.3.6.1.4.1.2544.1.11.3.18.23.1.5
Object
column
FspR7-MIBApsType
Type of Automatic Protection Switching; triggered by standing conditions
Context
- MIB
- FspR7-LAYER2-MIB
- OID
.1.3.6.1.4.1.2544.1.11.3.18.23.1.5- Type
- column
- Access
- readonly
- Status
- current
- Parent
- flowProtectionStatusEntry
- Table
- flowProtectionStatusTable
- Siblings
- 11
Values & Constraints
Type Values
0 | undefined |
2 | line |
3 | sncN |
4 | sncI |
5 | sncS |
6 | eth |
7 | phys |
8 | sncNPM |
9 | sncNTCM |
10 | sncISM |
11 | mux |
12 | pcs |
13 | ethSncI |
14 | ethSncN |
15 | ethSncS |
16 | ethSncT |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| flowProtectionStatusWorkingEthIndex The entityIndex (ETH part) of the working section in the APS group. | column | ADVA-MIBEntityIndex | .1.3.6.1.4.1.2544.1.11.3.18.23.1.1 |
| flowProtectionStatusBridge obsolete To select between diffenrent protection types | column | FspR7L2Brigde | .1.3.6.1.4.1.2544.1.11.3.18.23.1.10 |
| flowProtectionStatusLevelDomainMonitored Maintenance Domain Level monitored | column | FspR7L2LevelDomainMonitored | .1.3.6.1.4.1.2544.1.11.3.18.23.1.11 |
| flowProtectionStatusBridgeType To select between diffenrent protection types | column | FspR7L2Brigde | .1.3.6.1.4.1.2544.1.11.3.18.23.1.12 |
| flowProtectionStatusWorkingFlwIndex The entityIndex (FLW part) of the working section in the APS group. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2544.1.11.3.18.23.1.2 |
| flowProtectionStatusProtectionEthIndex The entityIndex (ETH part) of the protection section in the APS group. | column | ADVA-MIBEntityIndex | .1.3.6.1.4.1.2544.1.11.3.18.23.1.3 |
| flowProtectionStatusProtectionFlwIndex The entityIndex (FLW part) of the protection section in the APS group. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2544.1.11.3.18.23.1.4 |
| flowProtectionStatusProtectionType This describes the topology and level of the protection (OCH or
OM -Level on a ring; Line in PT-PT and Line or Dualhomed on a Feeder). | column | FspR7-MIBFspR7ProtectionType | .1.3.6.1.4.1.2544.1.11.3.18.23.1.6 |
| flowProtectionStatusProtectionMech Port Based refers to HST Cards and Switches: Card Based refers to additional equipment protection | column | ADVA-MIBProtectionMech | .1.3.6.1.4.1.2544.1.11.3.18.23.1.7 |
| flowProtectionStatusDirection Bi-Directional | Unidirectional setup used in protection setup: Not to be used by others | column | FspR7-MIBApsDirection | .1.3.6.1.4.1.2544.1.11.3.18.23.1.8 |
| flowProtectionStatusRevertiveMode Revertive Protection Switching | column | FspR7-MIBApsRevertMode | .1.3.6.1.4.1.2544.1.11.3.18.23.1.9 |