print-density
FUTURESMART-MIB ·
.1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1.5
Object
scalar
optional
r/w
Integer32
Returns or sets the print density setting. Print density is the instantaneous amount of marking agent applied to the paper while printing. A value of zero has the lowest print density, yielding a lighter page. A value of 10 has the highest print density, yielding a darker page. Each POS should document what values in the 0 to 10 range are supported
Context
- MIB
- FUTURESMART-MIB
- OID
.1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1.5- Type
- scalar
- Access
- readwrite
- Status
- optional
- Parent
- settings-prt-eng
- Siblings
- 8
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-10
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| override-media-name optional Sets a string identifying the media name that is to be used in
place of the currently requested media. The substitution will
continue until another media is selected. If set to a … | scalar | OctetString | .1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1.2 |
| duplex-blank-pages optional When the value of the device-system variable is set to
eDuplexBlankPagesAuto, it means to Smart Duplex in any of the
specified conditions. This selection is logically equivalent t… | scalar | Enumeration | .1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1.28 |
| override-media-size optional Sets the media size that is to be used in place of the
currently requested media size | scalar | Enumeration | .1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1.3 |
| finisher-image-rotation optional This PML object will provide the additional image rotation that
is applied to a printed job depending on the presence or
absence of a finisher device or the value of the
SVM_ALWAY… | scalar | OctetString | .1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1.31 |
| cartridge-adaptive-gain optional The Adaptive TA Gain is stored for the last 5 cartridges.
Cartridge one is the most recent to be installed (current), and
cartridge 5 is least recent to be installed. This object … | scalar | Integer32 | .1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1.36 |
| cartridge-adaptive-gain-reset optional This object will Reset the Adaptive TA Gain value to 1 0 and
disable the adaptive TA routine. The value that this object
returns is stored in non-volatile memory | scalar | Enumeration | .1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1.37 |
| supplies-at-very-low-setting optional This object can be used to change the setting of menu item AT
VERY LOW. The behavior of the printer when a supply reaches low
changes in accordance with the setting of this PML Ob… | scalar | Enumeration | .1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1.38 |
| marking-agent-density | node | - | .1.3.6.1.4.1.11.2.3.9.4.2.1.4.1.1.9 |