flowReaderLastTime

FLOW-METER-MIB · .1.3.6.1.2.1.40.1.3.1.4

Object

column r/w SNMPv2-TCTimeStamp
Time this meter reader began its most recent data collection.
              
This variable should be written by a meter reader as its first
step in reading flow data.  The meter will set this LastTime
value to its current Uptime, and set its PreviousTime value
(below) to the old  LastTime.  This allows the meter to
recover flows which have been inactive since PreviousTime,
for these have been collected at least once.
              
If the meter reader fails to write flowLastReadTime, collection
may still proceed but the meter may not be able to recover
inactive flows until the flowReaderTimeout has been reached
for this entry.

Context

MIB
FLOW-METER-MIB
OID
.1.3.6.1.2.1.40.1.3.1.4
Type
column
Access
readwrite
Status
current
Parent
flowReaderInfoEntry
Table
flowReaderInfoTable
Siblings
6

Syntax

SNMPv2-TCTimeStamp
Source
SNMPv2-TCTimeStamp
Base type
Unsigned32

Values & Constraints

No enumerated values or constraints recorded.

Related Objects

Sibling Objects