flWorkFWCtrlLoginExpire

FL-MGD-INFRASTRUCT-MIB · .1.3.6.1.4.1.4346.11.11.11.2.3.3

Object

scalar r/w Integer32
When the user configures the device using the web interface
it is necessary to enter the password. After the first
authentication the user is registered for the log in expiring
time and it is not necessary to enter the password again.
After the expiration of the login expiring time the user will
be invite to enter the password again.
The login expiring time can be chosen in the range from 30 up
to 3600 seconds. The value of zero disables the automatically
login.
The granularity of this timer is 1 second.

Context

MIB
FL-MGD-INFRASTRUCT-MIB
OID
.1.3.6.1.4.1.4346.11.11.11.2.3.3
Type
scalar
Access
readwrite
Status
current
Parent
flWorkFWCtrlPasswd
Siblings
2

Syntax

Integer32

Values & Constraints

Object Constraints
range: 30-3600