mpsSysConfigCountry
FEC-MPS-MIB ·
.0.53.1.1.1
Object
scalar
r/w
Enumeration
This variable contains the country code settings of the PBX, e.g. change CLIP information at calls to exter, change impedance settings at internal analogue ports.
Context
- MIB
- FEC-MPS-MIB
- OID
.0.53.1.1.1- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- mpsSysConfig
- Siblings
- 12
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | germany |
2 | netherlands |
3 | united-kindom |
4 | belgium |
5 | italy |
6 | denmark |
7 | spain |
8 | sweden |
9 | norway |
10 | france |
11 | portugal |
12 | austria |
13 | switzerland |
14 | czech |
15 | slovenia |
16 | poland |
17 | hungary |
18 | greece |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| mpsSysConfigDefaultTargetType This variable contains the default target type of system, if no
incoming external call distribution match. 'off' means busy
signalling to external subscriber. | scalar | Enumeration | .0.53.1.1.10 |
| mpsSysConfigDefaultTargetIndex This variable contains index of the target table or zero (busy
signalling),
mpsSysConfigDefaultTargetType=group : index = mpsGroupIndex.
mpsSysConfigDefaultTargetType=extens… | scalar | Integer32 | .0.53.1.1.11 |
| mpsSysConfigExtMoHVolume This variable contains the volume adjustment level for the external
MoH played back via the audio-in jack (approximately in 3 dB steps):
negative values -> attenuate during playba… | scalar | Integer32 | .0.53.1.1.12 |
| mpsSysConfigPreselectionCode This variable contains the digits for system preselection
(call-by-call). | scalar | OctetString | .0.53.1.1.13 |
| mpsSysConfigSetExchangeDate obsolete Accept time and date is off, acceppt from exchange or accept
from time server. | scalar | Enumeration | .0.53.1.1.2 |
| mpsSysConfigFacilities System facilities:
highRingerFrequency: a/b extension ringing frequency (0=50
Hz, 1=25 Hz)
handoverBusyExtension: This value determines if handover to
busy extension is possibl… | scalar | Bits | .0.53.1.1.3 |
| mpsSysConfigAreaCode This variable contains the digits for the area code (national
number, e.g. '5171'). | scalar | OctetString | .0.53.1.1.4 |
| mpsSysConfigCountryCode This variable contains the digits for the country code
(international number, e.g '49'). | scalar | OctetString | .0.53.1.1.5 |
| mpsSysConfigCodeInternationalPrefix This variable contains the digits for international prefix code. | scalar | OctetString | .0.53.1.1.6 |
| mpsSysConfigCodeNationalPrefix This variable contains the digit for national prefix code. | scalar | OctetString | .0.53.1.1.7 |
| mpsSysConfigCityCode This variable contains the digit for the city code prefix.
Extension with dial authorisation = 'local' can only dial numbers
with this prefix. | scalar | OctetString | .0.53.1.1.8 |
| mpsSysConfigLanguage This variable contains the language code setting, e.g for system
provided menue. | scalar | Enumeration | .0.53.1.1.9 |