mpsSysChargeHiddenDigitsCountB
FEC-MPS-MIB ·
.0.53.1.3.9
Object
scalar
r/w
Integer32
You can enter the number of hidden digit positions for outgoing calls. The positions (numbers) are concealed from right to left (from the end of the number). -1 = hide all
Context
- MIB
- FEC-MPS-MIB
- OID
.0.53.1.3.9- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- mpsSysCharge
- Siblings
- 12
Syntax
Integer32
Values & Constraints
Object Constraints
range: -1-20
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| mpsSysChargeProtocol This value determine the charging protocol on the internal isdn
ports. You have three options here: KEYPAD protocol - Charge data
is transferred such that it can be displayed di… | scalar | Enumeration | .0.53.1.3.1 |
| mpsSysChargeSaveOutgoingCall System setting for saving call data records for outgoing calls:
never(1) : no call data records for outgoing calls saved.
all(2) : save call data records for a… | scalar | Enumeration | .0.53.1.3.10 |
| mpsSysChargeSaveIncomingCall System setting for saving call data records for incoming calls:
never(1) : no call data records for incoming calls saved.
all(2) : save call data records for a… | scalar | Enumeration | .0.53.1.3.11 |
| mpsSysChargePrintingHost This variable contains the host name for printing call data record.
For local printing (serial printer), set to 'localhost'.
For disable leave string empty. | scalar | SNMPv2-TCDisplayString | .0.53.1.3.12 |
| mpsSysChargePrintingTcpPort This variable contains the tcp port for printing call data record.
For local printing (serial printer), set to an arbitrary port
matching that one in soipConfigTable. | scalar | SNMPv2-SMIInteger32 | .0.53.1.3.13 |
| mpsSysChargeFrequency obsolete This value determine the frequency of the charge pulse for
analogue terminals. | scalar | Enumeration | .0.53.1.3.2 |
| mpsSysChargeIncomingCall obsolete You can define whether acquisition is to be made for all
connection (1), or only when a project number is input (2). | scalar | SNMPv2-TCTruthValue | .0.53.1.3.3 |
| mpsSysChargeMultiplier Charge rate multiplier.
e.g. 1 Unit = 0,064 -> mpsSysChargeMultiplier = 64,
mpsSysChargeExponent = -3.
1 Unit = 1,200 -> mpsSysChargeMultiplier = 12,
… | scalar | SNMPv2-SMIUnsigned32 | .0.53.1.3.4 |
| mpsSysChargeExponent Charge rate exponent.
e.g. 1 Unit = 0,064 -> mpsSysChargeMultiplier = 64,
mpsSysChargeExponent = -3.
1 Unit = 1,200 -> mpsSysChargeMultiplier = 12,
… | scalar | Integer32 | .0.53.1.3.5 |
| mpsSysChargeCurrencyName This currency name will be displayed by the terminal. | scalar | OctetString | .0.53.1.3.6 |
| mpsSysChargeExtensionIndex obsolete You can define an extension index at which internal telephone the
communication data overflow is to be signaled per uus1 message. | scalar | ExtensionIndexOrZero | .0.53.1.3.7 |
| mpsSysChargeHiddenDigitsCountA You can enter the number of hidden digit positions
for incoming calls. The positions (numbers) are
concealed from right to left (from the end of the
number).
-1 = hide all | scalar | Integer32 | .0.53.1.3.8 |