fddimibSMTConnectionPolicy

FDDI-SMT73-MIB · .1.3.6.1.2.1.10.15.73.1.2.1.14

Object

column mandatory r/w Integer32
A value representing the connection policies in
effect in a node. A station sets the corresponding
bit for each of the connection types that it
rejects. The letter designations, X and Y, in the
'rejectX-Y' names have the following significance:
X represents the PC-Type of the local PORT and Y
represents the PC_Type of the adjacent PORT
(PC_Neighbor). The evaluation of Connection-
Policy (PC-Type, PC-Neighbor) is done to determine
the setting of T- Val(3) in the PC-Signalling
sequence (refer to ANSI 9.6.3). Note that Bit 15,
(rejectM-M), is always set and cannot be cleared.
              
The value is a sum.  This value initially takes
the value zero, then for each of the connection
policies currently enforced on the node, 2 raised
to a power is added to the sum.  The powers are
according to the following table:
              
       Policy   Power
    rejectA-A     0
    rejectA-B     1
    rejectA-S     2
    rejectA-M     3
    rejectB-A     4
    rejectB-B     5
    rejectB-S     6
    rejectB-M     7
    rejectS-A     8
    rejectS-B     9
    rejectS-S     10
    rejectS-M     11
    rejectM-A     12
    rejectM-B     13
    rejectM-S     14
    rejectM-M     15

Context

MIB
FDDI-SMT73-MIB
OID
.1.3.6.1.2.1.10.15.73.1.2.1.14
Type
column
Access
readwrite
Status
mandatory
Parent
fddimibSMTEntry
Table
fddimibSMTTable
Siblings
25

Syntax

Integer32

Values & Constraints

Object Constraints
range: 32768-65535

Related Objects

Sibling Objects