f3PtpPTPClockClockSyncEEnabled

F3-PTP-MIB · .1.3.6.1.4.1.2544.1.12.18.1.19.1.26

Object

column r/w SNMPv2-TCTruthValue
This object allows to specify whether the Telecom Slave 
can be enabled/disabled for Synchronous Ethernet. 
When enabled, on receive side 
  -telecom slave can extract the frequency 
   and pass the recovered clock to the system clock
  -QL is extracted (when QL is enabled) from the selected SOOC's clock class
  -telecom slave is eligible to be selected as a system clock reference
When disabled, on receive side,
  -telecom slave does not pass the recovered clock to the system clock 
  -telecom slave does not process the QL from selected SOOC's clock class 
  -telecom slave is not eligible to be selected as a 
           system clock reference.

Context

MIB
F3-PTP-MIB
OID
.1.3.6.1.4.1.2544.1.12.18.1.19.1.26
Type
column
Access
readwrite
Status
current
Parent
f3PtpPTPClockEntry
Table
f3PtpPTPClockTable
Siblings
39

Syntax

SNMPv2-TCTruthValue
Source
SNMPv2-TCTruthValue
Base type
Enumeration

Values & Constraints

Type Values
1true
2false