loadB
ETA-RCI10-MIB ·
.1.3.6.1.4.1.44086.4.1.10.2.10.1.23
Object
column
SNMPv2-SMIInteger32
Load current in milliampere which flows throuth the fuse
Context
- MIB
- ETA-RCI10-MIB
- OID
.1.3.6.1.4.1.44086.4.1.10.2.10.1.23- Type
- column
- Access
- readonly
- Status
- current
- Parent
- fusesBEntry
- Table
- fusesBTable
- Siblings
- 25
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| indexB Fuse index | column | Integer32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.1 |
| errCrcProgB Program memory CRC fault: 0=no fault, 1=fault | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.10 |
| errIntMemB Internal memory fault: 0=no fault, 1=fault | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.11 |
| errControllerB Controller fault: 0=no fault, 1=fault | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.12 |
| errWatchdogB Watchdog reset fault: 0=no fault, 1=fault | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.13 |
| voltageB Power supply voltage in millivolt | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.14 |
| temperatureB Current temperature of the fuse in millivolt | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.15 |
| loadOutputB Output status of the fuse: 0=output off, 1=output on | column | Integer32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.16 |
| statusShortB Short is detected by this fuse: 0=no fault, 1=fault | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.17 |
| statusOverloadB Overload status: 0=no overload, 1=overload | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.18 |
| statusUvltB Undervoltage status: 0=no undervoltage, 1=undervoltage | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.19 |
| availableB Status of fuse: 0=no fuse, 1=fuse available | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.2 |
| statusOvltB Overvoltage status: 0=no overvoltage, 1=overvoltage | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.20 |
| statusOtmpB Overtemperature status: 0=no overtemperature, 1=overtemperature | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.21 |
| statusNoVccB No VCC status: 0=no VCC, 1=VCC ok | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.22 |
| labelB Label given for this fuse | column | OctetString | .1.3.6.1.4.1.44086.4.1.10.2.10.1.24 |
| nominalVoltageB Polarity and nominal voltage of the fuse in volt. E.g.: -48 | column | OctetString | .1.3.6.1.4.1.44086.4.1.10.2.10.1.25 |
| multiEsxB MultiEsx: Fuses are connected in parallel to protect higher nominal loads: 0=not connected, 1=connected to a lower slot index, 2=connected as first | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.26 |
| deviceTypeB Type number of the fuse | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.3 |
| serialB Serial number of the fuse | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.4 |
| hwVersionB Hardware version number of the fuse | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.5 |
| swVersionB Software version number of the fuse | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.6 |
| nominalCurrentB Nominal current of the fuse in milliampere | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.7 |
| errNoSysParB No systemparameter available fault: 0=no fault, 1=fault | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.8 |
| errCrcParamB Parameter CRC fault: 0=no fault, 1=fault | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.10.2.10.1.9 |