eaSwVersionA
ETA-RCI10-MIB ·
.1.3.6.1.4.1.44086.4.1.20.1.1.1.6
Object
column
SNMPv2-SMIInteger32
Software version number of the device
Context
- MIB
- ETA-RCI10-MIB
- OID
.1.3.6.1.4.1.44086.4.1.20.1.1.1.6- Type
- column
- Access
- readonly
- Status
- current
- Parent
- eaAEntry
- Table
- eaATable
- Siblings
- 35
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eaIndexA Device index (slot number) | column | Integer32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.1 |
| eaInput2A Status digital input2: 0=low, 1=high | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.10 |
| eaInput3A Status digital input3: 0=low, 1=high | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.11 |
| eaInput4A Status digital input4: 0=low, 1=high | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.12 |
| eaInput5A Status digital input5: 0=low, 1=high | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.13 |
| eaInput6A Status digital input6: 0=low, 1=high | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.14 |
| eaInput7A Status digital input7: 0=low, 1=high | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.15 |
| eaInput8A Status digital input8: 0=low, 1=high | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.16 |
| eaAnalogInputA Analog current input in mA | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.17 |
| eaLabelOutput1A Label for output1 of this EAI device | column | OctetString | .1.3.6.1.4.1.44086.4.1.20.1.1.1.18 |
| eaLabelOutput2A Label for output2 of this EAI device | column | OctetString | .1.3.6.1.4.1.44086.4.1.20.1.1.1.19 |
| eaAvailableA Status of the device: 0=no EAI device, 1=EEAI device available | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.2 |
| eaLabelInput1A Label for input1 of this EAI device | column | OctetString | .1.3.6.1.4.1.44086.4.1.20.1.1.1.20 |
| eaLabelInput2A Label for input2 of this EAI device | column | OctetString | .1.3.6.1.4.1.44086.4.1.20.1.1.1.21 |
| eaLabelInput3A Label for input3 of this EAI device | column | OctetString | .1.3.6.1.4.1.44086.4.1.20.1.1.1.22 |
| eaLabelInput4A Label for input4 of this EAI device | column | OctetString | .1.3.6.1.4.1.44086.4.1.20.1.1.1.23 |
| eaLabelInput5A Label for input5 of this EAI device | column | OctetString | .1.3.6.1.4.1.44086.4.1.20.1.1.1.24 |
| eaLabelInput6A Label for input6 of this EAI device | column | OctetString | .1.3.6.1.4.1.44086.4.1.20.1.1.1.25 |
| eaLabelInput7A Label for input7 of this EAI device | column | OctetString | .1.3.6.1.4.1.44086.4.1.20.1.1.1.26 |
| eaLabelInput8A Label for input8 of this EAI device | column | OctetString | .1.3.6.1.4.1.44086.4.1.20.1.1.1.27 |
| eaLabelAnalogInputA Label for the analog input of this EAI device | column | OctetString | .1.3.6.1.4.1.44086.4.1.20.1.1.1.28 |
| eaSignallingGroupOutput1A Signalling function for output1.
Syntax: 20 (for 20 slots) characters '0' or '1'.
'0'= signalling not active for this slot; '0'= signalling is active for this slot | column | OctetString | .1.3.6.1.4.1.44086.4.1.20.1.1.1.29 |
| eaDeviceTypeA Type number of the device | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.3 |
| eaSignallingActiveOutput1A Status of signalling function for output1: 0=not active, 1=active | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.30 |
| eaSignallingGroupOutput2A Signalling function for output2.
Syntax: 20 (for 20 slots) characters '0' or '1'.
'0'= signalling not active for this slot; '0'= signalling is active for this slot | column | OctetString | .1.3.6.1.4.1.44086.4.1.20.1.1.1.31 |
| eaSignallingActiveOutput2A Status of signalling function for output2: 0=not active, 1=active | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.32 |
| eaLogicFunctionOutput1A Logic function for output1.
Length: 40 characters. Syntax: Logic connections '*'=AND, '+'=OR, '!'=Negation;
Signals: EAI digital input 'eai<slot address>in<input number>', ESX sta… | column | OctetString | .1.3.6.1.4.1.44086.4.1.20.1.1.1.33 |
| eaLogicFunctionActiveOutput1A Status of logic function for output1: 0=not active, 1=active | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.34 |
| eaLogicFunctionOutput2A Logic function for output2.
Length: 40 characters. Syntax: Logic connections '*'=AND, '+'=OR, '!'=Negation;
Signals: EAI digital input 'eai<slot address>in<input number>', ESX sta… | column | OctetString | .1.3.6.1.4.1.44086.4.1.20.1.1.1.35 |
| eaLogicFunctionActiveOutput2A Status of logic function for output2: 0=not active, 1=active | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.36 |
| eaSerialA Serial number of the device | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.4 |
| eaHwVersionA Hardware version number of the device | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.5 |
| eaOutput1A Status of the relay output1: 0=output off, 1=output on (contact to normaly close is closed) | column | Integer32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.7 |
| eaOutput2A Status of the relay output2: 0=output off, 1=output on (contact to normaly close is closed) | column | Integer32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.8 |
| eaInput1A Status digital input1: 0=low, 1=high | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.44086.4.1.20.1.1.1.9 |