fsEoamErrorEventResend
EOAM-MIB ·
.1.3.6.1.4.1.2076.121.1.3
Object
scalar
r/w
Unsigned32
This object specifies the number of times an error event OAMPDU will be sent repeatedly. To avoid loss of OAMPDUs on faulty links, the events like symbol period, frame -period, frame, frame-secs-summary and organisation specific event are sent repeatedly.
Context
- MIB
- EOAM-MIB
- OID
.1.3.6.1.4.1.2076.121.1.3- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- fsEoamSystem
- Siblings
- 4
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 1-10
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| fsEoamSystemControl The administrative system control status of Ethernet
OAM module. The value 'start' (1) indicates that all
resources required by EOAM module should be allocated
and EOAM should be… | scalar | Enumeration | .1.3.6.1.4.1.10876.101.1.121.1.1 |
| fsEoamModuleStatus The administrative module status of Ethernet OAM module.
This enables or disables EOAM in the system. A value of
'enabled' (1) indicates that EOAM is enabled in the device
and c… | scalar | Enumeration | .1.3.6.1.4.1.10876.101.1.121.1.2 |
| fsEoamOui The Organizational Unique Identifier of the local EOAM
Client. This will be sent in the Information OAMPDU in
Local Information TLV.
Default for this object will be the first th… | scalar | EoamOui | .1.3.6.1.4.1.10876.101.1.121.1.4 |
| fsEoamTraceOption This object is used to enable trace statements in
Ethernat OAM module.
A four byte integer is used for enabling the trace level.
Each bit in the four byte integer represents … | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.10876.101.1.121.1.5 |