etsysTrackedObjectsRouteMetricDownThresh
ENTERASYS-TRACKED-OBJECTS-MIB ·
.1.3.6.1.4.1.5624.1.2.79.1.2.5.1.6
Object
column
r/w
Unsigned32
The threshold value the route metric MUST reach in order for
the tracked object to transition to the 'down' state from the
'up' state.
This value MUST be greater than the value specified in
etsysTrackedObjectsRouteMetricUpThresh. An inconsistentValue
error is returned if the value of a set operation is less than
or equal to etsysTrackedObjectsRouteMetricUpThresh.
This value only has meaning when etsysTrackedObjectsRouteOption
is 'metric'.
Context
- MIB
- ENTERASYS-TRACKED-OBJECTS-MIB
- OID
.1.3.6.1.4.1.5624.1.2.79.1.2.5.1.6- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- etsysTrackedObjectsRouteEntry
- Table
- etsysTrackedObjectsRouteTable
- Siblings
- 6
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 1-255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| etsysTrackedObjectsRouteType The address family of this tracked object entry. This object
dictates the valid input for the etsysTrackedObjectsRoutePrefix
and etsysTrackedObjectsRoute objects.
… | column | INET-ADDRESS-MIBInetAddressType | .1.3.6.1.4.1.5624.1.2.79.1.2.5.1.1 |
| etsysTrackedObjectsRoutePrefix The address mask of etsysTrackedObjectsRoute.
The value of this object MUST be set while creating the row
and it MAY NOT be modified afterwards. | column | INET-ADDRESS-MIBInetAddressPrefixLength | .1.3.6.1.4.1.5624.1.2.79.1.2.5.1.2 |
| etsysTrackedObjectsRoute The address of the route that is monitored by this tracked
object.
The value of this object MUST be set while creating the row
and it MAY NOT be modified afterwards. | column | INET-ADDRESS-MIBInetAddress | .1.3.6.1.4.1.5624.1.2.79.1.2.5.1.3 |
| etsysTrackedObjectsRouteOption Dictates what to monitor in relation to the address.
reachability(1) - Tracks the status of the route within the
FIB.
metric(2) - Uses metri… | column | Enumeration | .1.3.6.1.4.1.5624.1.2.79.1.2.5.1.4 |
| etsysTrackedObjectsRouteMetricUpThresh The threshold value the route metric MUST reach in order for
the tracked object to transition to the 'up' state from the
'down' state.
This value MUST be less than … | column | Unsigned32 | .1.3.6.1.4.1.5624.1.2.79.1.2.5.1.5 |
| etsysTrackedObjectsRouteStatus This object permits management of the table by facilitating
actions such as row creation and deletion.
Creation and activation of a conceptual row in this table MUS… | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.5624.1.2.79.1.2.5.1.7 |