etsysPsePortPDType
ENTERASYS-POWER-ETHERNET-EXT-MIB ·
.1.3.6.1.4.1.5624.1.2.50.1.5.1.1.3
Object
column
Enumeration
Describes the detected PD type on this port.
A value of legacy(1) - indicates that the PD is using a
capacitive signature, which is pre-IEEE standard.
A value of ieee8023af(2)- indicates that the PD is using a
resistive signature and is compliant with the IEEE Std 802.3af.
A value of other(3) - indicates that the PD type could not be
determined.
A value of ieee8023(4)- indicates that the PD is using a
resistive signature and is compliant with the IEEE Std 802.3af
and/or IEEE Std 802.3at specifications.
A value of ieee8023at(5)- indicates that the PD is using a
resistive signature and is compliant with the IEEE Std 802.3at.
Context
- MIB
- ENTERASYS-POWER-ETHERNET-EXT-MIB
- OID
.1.3.6.1.4.1.5624.1.2.50.1.5.1.1.3- Type
- column
- Access
- readonly
- Status
- current
- Parent
- etsysPsePortPowerManagementEntry
- Table
- etsysPsePortPowerManagementTable
- Siblings
- 5
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | legacy |
2 | ieee8023af |
3 | other |
4 | ieee8023 |
5 | ieee8023at |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| etsysPsePortPowerLimit This object sets the maximum power allowed on this port.
If the port exceeds its power limit, it will be shut down.
This object has effect only when its module is in realtime
mode… | column | milliwatts Integer32 | .1.3.6.1.4.1.5624.1.2.50.1.5.1.1.1 |
| etsysPsePortPowerUsage Actual power consumption measured in real-time. | column | milliwatts SNMPv2-SMIGauge32 | .1.3.6.1.4.1.5624.1.2.50.1.5.1.1.2 |
| etsysPsePortCapability This object indicates the IEEE Power over Ethernet standard
this port supports. | column | Bits | .1.3.6.1.4.1.5624.1.2.50.1.5.1.1.4 |
| etsysPsePortCapabilitySelect This object sets the port's power management capabilities
based on the IEEE standard.
ieee8023af (1) : IEEE Std 802.3af
ieee8023at (2) : IEEE Std 802.3at
… | column | Enumeration | .1.3.6.1.4.1.5624.1.2.50.1.5.1.1.5 |
| etsysPsePortDetectionStatus Describes the operational status of the port PD detection.
A value of disabled(1)- indicates that the PSE State diagram
is in the state DISABLED.