etsysFlowLimitingSystemSnmpNotifications
ENTERASYS-FLOW-LIMITING-MIB ·
.1.3.6.1.4.1.5624.1.2.43.1.1.2
Object
The current state of the SNMP Notification functionality in
the Flow Limiting feature.
enabled (1) - Flow Limiting will generate SNMP Notifications
for flow counts and setup rates that exceed the
configured limits. The Flow Limiting feature
MUST be enabled for SNMP Notifications to be
generated.
disabled (2) - Flow Limiting will not generate SNMP
Notifications under any conditions.
A notification is generated when a value is first detected
above its respective configured limit. That notification
MUST NOT be generated again until the respective value has
transitioned through its respective limit in both directions.
Agents are not required to generate SNMP Notifications for
conditions that exist when this object is set to enabled.
SNMP Notifications MAY only be generated after additional
flow setups are detected that exceed the configured limits
on that interface.
Maintaining the value of this object across agent reboots is
REQUIRED.
Context
- MIB
- ENTERASYS-FLOW-LIMITING-MIB
- OID
.1.3.6.1.4.1.5624.1.2.43.1.1.2- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- etsysFlowLimitingSystemBranch
- Siblings
- 6
Syntax
P-BRIDGE-MIBEnabledStatus
- Source
- P-BRIDGE-MIBEnabledStatus
- Base type
Enumeration
Values & Constraints
Type Values
1 | enabled |
2 | disabled |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| etsysFlowLimitingSystemState The current state of the active part of the Flow Limiting
feature.
enabled (1) - All aspects of Flow Limiting are operational.
disabled (2) - Flow Limiting … | scalar | P-BRIDGE-MIBEnabledStatus | .1.3.6.1.4.1.5624.1.2.43.1.1.1 |
| etsysFlowLimitingSystemInterfaceShutdown The current state of the interface shutdown functionality in
the Flow Limiting feature.
enabled (1) - Flow Limiting will shutdown an interface when
the … | scalar | P-BRIDGE-MIBEnabledStatus | .1.3.6.1.4.1.5624.1.2.43.1.1.3 |
| etsysFlowLimitingSystemNotificationInterval The number of seconds to wait before generating another
notification of the same type for the same interface.
This allows notification generation to be throttled in
the case of a … | scalar | seconds Unsigned32 | .1.3.6.1.4.1.5624.1.2.43.1.1.4 |
| etsysFlowLimitingSystemClearStats When set to true(1) the following objects in all rows of
the etsysFlowLimitingInterfaceTable MUST be set to zero:
etsysFlowLimitingIntfFlowCountMaxTime
etsysFlowLim… | scalar | SNMPv2-TCTruthValue | .1.3.6.1.4.1.5624.1.2.43.1.1.5 |
| etsysFlowLimitingSystemMaxSupportedFlowCount The maximum number of flows supported on this entity. | scalar | flows SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.5624.1.2.43.1.1.6 |
| etsysFlowLimitingSystemMaxSupportedSetupRate The maximum flow setup rate supported on this entity. | scalar | flows/second SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.5624.1.2.43.1.1.7 |