pduUnitPropertiesCircuitBreakerCount
ENLOGIC-PDU2-MIB ·
.1.3.6.1.4.1.38446.1.2.3.1.7
Object
column
Integer32
The total number of circuit breaker on the PDU
Context
- MIB
- ENLOGIC-PDU2-MIB
- OID
.1.3.6.1.4.1.38446.1.2.3.1.7- Type
- column
- Access
- readonly
- Status
- current
- Parent
- pduUnitPropertiesEntry
- Table
- pduUnitPropertiesTable
- Siblings
- 15
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pduUnitPropertiesIndex The index of the PDU properties table entry | column | Integer32 | .1.3.6.1.4.1.38446.1.2.3.1.1 |
| pduUnitPropertiesRatedVoltage The PDU voltage rating in Volts | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.38446.1.2.3.1.10 |
| pduUnitPropertiesRatedMaxCurrent The PDU current rating in Amps | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.38446.1.2.3.1.11 |
| pduUnitPropertiesRatedFrequency The PDU frequency rating in Hz | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.38446.1.2.3.1.12 |
| pduUnitPropertiesRatedPower The PDU VA (VoltAmps) rating. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.38446.1.2.3.1.13 |
| pduUnitPropertiesOrientation The PDU orientation | column | Enumeration | .1.3.6.1.4.1.38446.1.2.3.1.14 |
| pduUnitPropertiesOutletLayout The outlet layout for the PDU. Getting this OID will return outlet layout for the device.
seqPhaseToNeutral(1) indicates outlet layout as follows:
1:1-N,2:2-N,3:3-N,4:1-N,5:2-N,..… | column | Enumeration | .1.3.6.1.4.1.38446.1.2.3.1.15 |
| pduUnitPropertiesDaisyChainMemberType The daisy-chain member type | column | Enumeration | .1.3.6.1.4.1.38446.1.2.3.1.16 |
| pduUnitPropertiesName A user-defined string identifying the PDU | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.38446.1.2.3.1.2 |
| pduUnitPropertiesOutletCount The total number of outlets on the PDU | column | Integer32 | .1.3.6.1.4.1.38446.1.2.3.1.3 |
| pduUnitPropertiesSwitchedOutletCount The total number of switched outlets on the PDU | column | Integer32 | .1.3.6.1.4.1.38446.1.2.3.1.4 |
| pduUnitPropertiesMeteredOutletCount The total number of metered outlets on the PDU | column | Integer32 | .1.3.6.1.4.1.38446.1.2.3.1.5 |
| pduUnitPropertiesInputPhaseCount The total number of phases on the PDU | column | Integer32 | .1.3.6.1.4.1.38446.1.2.3.1.6 |
| pduUnitPropertiesMaxExternalSensorCount The maximum number of external sensors that can be connected to the PDU | column | Integer32 | .1.3.6.1.4.1.38446.1.2.3.1.8 |
| pduUnitPropertiesConnExternalSensorCount The current number of external sensors connected to the PDU | column | Integer32 | .1.3.6.1.4.1.38446.1.2.3.1.9 |