modifierDialedNumberModification

ELTEX-FXS72 · .1.3.6.1.4.1.35265.1.9.48.1.4

Object

column r/w SNMPv2-TCDisplayString
Dialed number modification (max len 29)
Allowed symbols:
	- '.', '-' - digit removing
	- 'X', 'x' - digit or symbol on this position is unchanging (mandatory);
	- '?' - digit or symbol on this position is unchanging (not mandatory);
	- '+' - next symblos will be added
	- '!' - end of parsing; all next symbols will be cutted
	- '$' - end of parsing; all next symbols will be unchanged
	- 0-9, '#', ‘*’ (without '+') - digit or symbol on this position will be replaced

Context

MIB
ELTEX-FXS72
OID
.1.3.6.1.4.1.35265.1.9.48.1.4
Type
column
Access
readwrite
Status
current
Parent
modifiersEntry
Table
modifiersTable
Siblings
5

Syntax

SNMPv2-TCDisplayString
Source
SNMPv2-TCDisplayString
Base type
OctetString

Values & Constraints

Type Constraints
range: 0..255