pme1008AlmSfpDdmWarningPortn
EKINOPS-Pme1008-MIB ·
.1.3.6.1.4.1.20044.79.2.2.3.8.1.10
Object
column
EKINOPS-MIBEkiOnOff
Warning On Client Trscv DDM :This OID indicates a warning is being received from the Client Transceiver DDM <Help> This alarm indicates if a DDM Warning has been detected on the client transceiver <Condtype> SFP_DDM_WARNING_1 <Probcause> inputOutputDeviceError (24) <Alarmtype> synthesisAlarm (12) <Polarity> (2)
Context
- MIB
- EKINOPS-Pme1008-MIB
- OID
.1.3.6.1.4.1.20044.79.2.2.3.8.1.10- Type
- column
- Access
- readonly
- Status
- current
- Parent
- pme1008AlmsynthAlmPortEntry
- Table
- pme1008AlmsynthAlmPortTable
- Siblings
- 11
Syntax
EKINOPS-MIBEkiOnOff
- Source
- EKINOPS-MIBEkiOnOff
- Base type
Enumeration
Values & Constraints
Type Values
1 | off |
2 | on |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pme1008AlmsynthAlmPortIndex Index definition for the pme1008AlmsynthAlmPort
table | column | Integer32 | .1.3.6.1.4.1.20044.79.2.2.3.8.1.1 |
| pme1008AlmSfpDdmAlmPortn Alarm On Client Trscv DDM :This
OID indicates an alarm is being
received from the Client Transceiver
DDM <Help> This alarm indicates
if a DDM Alarm has been detected
on the c… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.3.8.1.11 |
| pme1008AlmFailAccPortn Client Access Fail :This OID indicates
a failure on the Client port <Help>
This alarm indicates a failure
on the Client port <Condtype>
FAIL_ACC_1 <Probcause> equipmentMalfunc… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.3.8.1.13 |
| pme1008AlmUpCsfPortn Client Signal Fail Inserted :This
OID indicates a CSF has been inserted
in the upstream client port. <Help>
This status indicates if a Client
Signal Fail is currently inserted… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.3.8.1.17 |
| pme1008AlmSfpAbsentPortn Client SFP Absent :This OID indicates
that the Transceiver is not present
in the client port. <Help> This
alarm indicates if the client transceiver
is not plugged <Condtype> S… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.3.8.1.2 |
| pme1008AlmDdmAbsentPortn DDM Supported On Client Trscv
:This OID indicates that the Client
transceiver supports the Digital
Diagnostic Monitoring function
<Help> This status indicates if
the client t… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.3.8.1.3 |
| pme1008AlmHwFailAccPortn Client HW Fail :This OID indicates
a failure on client port, most
probably caused by a HW issue.
<Help> This alarm indicates a failure
on client port, most probably caused
by… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.3.8.1.5 |
| pme1008AlmDwLsdPortn Client SFP Laser Shutdown :This
OID indicates the Client transceiver
laser is shutdown <Help> This status
indicates if the client transceiver
laser is shutdown <Condtype> DW_L… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.3.8.1.6 |
| pme1008AlmClientLocalOosPortn Local Client Port In Service :This
OID indicates that the local Client
port is In Service (1) or Out of
Service (2) <Help> This status
indicates if the local client
port is i… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.3.8.1.7 |
| pme1008AlmClientRemoteOosPortn Remote Client Port In Service
:This OID indicates that the remote
Client port is In Service (1) or
Out of Service (2) <Help> This
status indicates if the remote
client port i… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.3.8.1.8 |
| pme1008AlmDwCaisPortn Client AIS Inserted :This OID
indicates a CAIS has been inserted
on the output client port. <Help>
This status indicates if a Client
Alarm Indication Signal is currently
inse… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.3.8.1.9 |