pme1008AlmClientVccLowAlaPortn
EKINOPS-Pme1008-MIB ·
.1.3.6.1.4.1.20044.79.2.2.2.216.1.6
Object
column
EKINOPS-MIBEkiOnOff
Client Trscv Power Supply Low :This OID indicates that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Help> Alarm indicating that the Trscv power supply of port is lower than the threshold value written in the Trscv EEPROM <Condtype> CLIENT_VCC_LOW_ALA_1 <Probcause> powerProblem (36) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
Context
- MIB
- EKINOPS-Pme1008-MIB
- OID
.1.3.6.1.4.1.20044.79.2.2.2.216.1.6- Type
- column
- Access
- readonly
- Status
- current
- Parent
- pme1008AlmclientSfpAlmDdmEntry
- Table
- pme1008AlmclientSfpAlmDdmTable
- Siblings
- 10
Syntax
EKINOPS-MIBEkiOnOff
- Source
- EKINOPS-MIBEkiOnOff
- Base type
Enumeration
Values & Constraints
Type Values
1 | off |
2 | on |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pme1008AlmclientSfpAlmDdmIndex Index definition for the pme1008AlmclientSfpAlmDdm
table | column | Integer32 | .1.3.6.1.4.1.20044.79.2.2.2.216.1.1 |
| pme1008AlmClientRxPwrLowAlaPortn Client Trscv Rx Power Low :This
OID indicates that the Trscv input
power of port is lower than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.2.216.1.16 |
| pme1008AlmClientRxPwrHighAlaPortn Client Trscv Rx Power High :This
OID indicates that the Trscv input
power of port is higher than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that … | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.2.216.1.17 |
| pme1008AlmClientTxPwrLowAlaPortn Client Trscv Tx Power Low :This
OID indicates that the Trscv output
power of port is lower than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that t… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.2.216.1.2 |
| pme1008AlmClientTxPwrHighAlaPortn Client Trscv Tx Power High :This
OID indicates that the Trscv output
power of port is higher than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.2.216.1.3 |
| pme1008AlmClientTxBiasLowAlaPortn Client Trscv Bias Low :This OID
indicates that the Trscv laser
bias current of port is lower
than the threshold value written
in the Trscv EEPROM <Help> Alarm
indicating that… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.2.216.1.4 |
| pme1008AlmClientTxBiasHighAlaPortn Client Trscv Bias High :This OID
indicates that the Trscv laser
bias current of port is higher
than the threshold value written
in the Trscv EEPROM <Help> Alarm
indicating th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.2.216.1.5 |
| pme1008AlmClientVccHighAlaPortn Client Trscv Power Supply High
:This OID indicates that the Trscv
power supply of port is higher
than the threshold value written
in the Trscv EEPROM <Help> Alarm
indicating … | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.2.216.1.7 |
| pme1008AlmClientTempLowAlaPortn Client Trscv Temp Low :This OID
indicates that the Trscv temperature
of port is lower than the threshold
value written in the Trscv EEPROM
<Help> Alarm indicating that the
Tr… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.2.216.1.8 |
| pme1008AlmClientTempHighAlaPortn Client Trscv Temp High :This OID
indicates that the Trscv temperature
of port is higher than the threshold
value written in the Trscv EEPROM
<Help> Alarm indicating that the
… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.2.216.1.9 |