pme1008AlmClientRxPwrLowWngPortn
EKINOPS-Pme1008-MIB ·
.1.3.6.1.4.1.20044.79.2.2.1.232.1.16
Object
column
EKINOPS-MIBEkiOnOff
Client Trscv Rx Power Low Warning :This OID indicates that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv input power is lower than the threshold value written in the Trscv EEPROM <Condtype> CLIENT_RX_PWR_LOW_WNG_1 <Probcause> receiveFailure (41) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
Context
- MIB
- EKINOPS-Pme1008-MIB
- OID
.1.3.6.1.4.1.20044.79.2.2.1.232.1.16- Type
- column
- Access
- readonly
- Status
- current
- Parent
- pme1008AlmclientSfpWarnDdmEntry
- Table
- pme1008AlmclientSfpWarnDdmTable
- Siblings
- 10
Syntax
EKINOPS-MIBEkiOnOff
- Source
- EKINOPS-MIBEkiOnOff
- Base type
Enumeration
Values & Constraints
Type Values
1 | off |
2 | on |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pme1008AlmclientSfpWarnDdmIndex Index definition for the pme1008AlmclientSfpWarnDdm
table | column | Integer32 | .1.3.6.1.4.1.20044.79.2.2.1.232.1.1 |
| pme1008AlmClientRxPwrHighWngPortn Client Trscv Rx Power High Warning
:This OID indicates that the Trscv
input power is higher than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
tha… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.1.232.1.17 |
| pme1008AlmClientTxPwLowWngPortn Client Trscv Tx Power Low Warning
:This OID indicates that the Trscv
output power is lower than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
that… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.1.232.1.2 |
| pme1008AlmClientTxPwrHighWngPortn Client Trscv Tx Power High Warning
:This OID indicates that the Trscv
output power is higher than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.1.232.1.3 |
| pme1008AlmClientTxBiasLowWngPortn Client Trscv Bias Low Warning
:This OID indicates that the Trscv
laser bias current is lower than
the threshold value written in
the Trscv EEPROM <Help> Warning
indicating th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.1.232.1.4 |
| pme1008AlmClientTxBiasHighWngPortn Client Trscv Bias High Warning
:This OID indicates that the Trscv
laser bias current is higher than
the threshold value written in
the Trscv EEPROM <Help> Warning
indicating … | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.1.232.1.5 |
| pme1008AlmClientVccLowWngPortn Client Trscv Power Supply Low
Warning :This OID indicates that
the Trscv power supply is lower
than the threshold value written
in the Trscv EEPROM <Help> Warning
indicating … | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.1.232.1.6 |
| pme1008AlmClientVccHighWngPortn Client Trscv Power Supply High
Warning :This OID indicates that
the Trscv power supply is higher
than the threshold value written
in the Trscv EEPROM <Help> Warning
indicatin… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.1.232.1.7 |
| pme1008AlmClientTempLowWngPortn Client Trscv Temp Low Warning
:This OID indicates that the Trscv
temperature is lower than the threshold
value written in the Trscv EEPROM
<Help> Warning indicating that
the … | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.1.232.1.8 |
| pme1008AlmClientTempHighWngPortn Client Trscv Temp High Warning
:This OID indicates that the Trscv
temperature is higher than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
that th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.79.2.2.1.232.1.9 |