pm200fr20AlmLineTxBiasHighWngPortn
EKINOPS-Pm200fr20-MIB ·
.1.3.6.1.4.1.20044.87.2.3.1.104.1.5
Object
column
EKINOPS-MIBEkiOnOff
Client Trscv Bias High Warning :This OID indicates that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Help> Warning indicating that the Trscv laser bias current is higher than the threshold value written in the Trscv EEPROM <Condtype> LINE_TX_BIAS_HIGH_WNG_1 <Probcause> transmitterFailure (56) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
Context
- MIB
- EKINOPS-Pm200fr20-MIB
- OID
.1.3.6.1.4.1.20044.87.2.3.1.104.1.5- Type
- column
- Access
- readonly
- Status
- current
- Parent
- pm200fr20AlmlineQsfpWarnDdmEntry
Syntax
EKINOPS-MIBEkiOnOff
Values & Constraints
No enumerated values or constraints recorded.