pm10010ulhAlmclientSfpWarnDdmEntry
EKINOPS-Pm10010ulh-MIB ·
.1.3.6.1.4.1.20044.80.2.2.1.272.1
Object
row
Row definition for the pm10010ulhAlmclientSfpWarnDdm table
Context
- MIB
- EKINOPS-Pm10010ulh-MIB
- OID
.1.3.6.1.4.1.20044.80.2.2.1.272.1- Type
- row
- Status
- current
- Parent
- pm10010ulhAlmclientSfpWarnDdmTable
- Table
- pm10010ulhAlmclientSfpWarnDdmTable
- Children
- 11
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pm10010ulhAlmclientSfpWarnDdmIndex Index definition for the pm10010ulhAlmclientSfpWarnDdm
table | column | Integer32 | .1.3.6.1.4.1.20044.80.2.2.1.272.1.1 |
| pm10010ulhAlmRxPwrLowWngPortn Client Trscv Rx Power Low Warning
:This OID indicates that the Trscv
input power is lower than the threshold
value written in the Trscv EEPROM
<Help> Warning indicating that
… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.272.1.16 |
| pm10010ulhAlmRxPwrHighWngPortn Client Trscv Rx Power High Warning
:This OID indicates that the Trscv
input power is higher than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
tha… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.272.1.17 |
| pm10010ulhAlmTxPwLowWngPortn Client Trscv Tx Power Low Warning
:This OID indicates that the Trscv
output power is lower than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
that… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.272.1.2 |
| pm10010ulhAlmTxPwrHighWngPortn Client Trscv Tx Power High Warning
:This OID indicates that the Trscv
output power is higher than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.272.1.3 |
| pm10010ulhAlmTxBiasLowWngPortn Client Trscv Bias Low Warning
:This OID indicates that the Trscv
laser bias current is lower than
the threshold value written in
the Trscv EEPROM <Help> Warning
indicating th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.272.1.4 |
| pm10010ulhAlmTxBiasHighWngPortn Client Trscv Bias High Warning
:This OID indicates that the Trscv
laser bias current is higher than
the threshold value written in
the Trscv EEPROM <Help> Warning
indicating … | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.272.1.5 |
| pm10010ulhAlmVccLowWngPortn Client Trscv Power Supply Low
Warning :This OID indicates that
the Trscv power supply is lower
than the threshold value written
in the Trscv EEPROM <Help> Warning
indicating … | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.272.1.6 |
| pm10010ulhAlmVccHighWngPortn Client Trscv Power Supply High
Warning :This OID indicates that
the Trscv power supply is higher
than the threshold value written
in the Trscv EEPROM <Help> Warning
indicatin… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.272.1.7 |
| pm10010ulhAlmTempLowWngPortn Client Trscv Temp Low Warning
:This OID indicates that the Trscv
temperature is lower than the threshold
value written in the Trscv EEPROM
<Help> Warning indicating that
the … | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.272.1.8 |
| pm10010ulhAlmTempHighWngPortn Client Trscv Temp High Warning
:This OID indicates that the Trscv
temperature is higher than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
that th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.272.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| pm10010ulhAlmclientSfpWarnDdmIndex Index definition for the pm10010ulhAlmclientSfpWarnDdm
table | column | Integer32 | .1.3.6.1.4.1.20044.80.2.2.1.272.1.1 |