pm10010ulhAlmclientSfpAlmDdmEntry
EKINOPS-Pm10010ulh-MIB ·
.1.3.6.1.4.1.20044.80.2.2.2.240.1
Object
row
Row definition for the pm10010ulhAlmclientSfpAlmDdm table
Context
- MIB
- EKINOPS-Pm10010ulh-MIB
- OID
.1.3.6.1.4.1.20044.80.2.2.2.240.1- Type
- row
- Status
- current
- Parent
- pm10010ulhAlmclientSfpAlmDdmTable
- Table
- pm10010ulhAlmclientSfpAlmDdmTable
- Children
- 11
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pm10010ulhAlmclientSfpAlmDdmIndex Index definition for the pm10010ulhAlmclientSfpAlmDdm
table | column | Integer32 | .1.3.6.1.4.1.20044.80.2.2.2.240.1.1 |
| pm10010ulhAlmRxPwrLowAlaPortn Client Trscv Rx Power Low :This
OID indicates that the Trscv input
power of port is lower than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.2.240.1.16 |
| pm10010ulhAlmRxPwrHighAlaPortn Client Trscv Rx Power High :This
OID indicates that the Trscv input
power of port is higher than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that … | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.2.240.1.17 |
| pm10010ulhAlmTxPwrLowAlaPortn Client Trscv Tx Power Low :This
OID indicates that the Trscv output
power of port is lower than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that t… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.2.240.1.2 |
| pm10010ulhAlmTxPwrHighAlaPortn Client Trscv Tx Power High :This
OID indicates that the Trscv output
power of port is higher than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.2.240.1.3 |
| pm10010ulhAlmTxBiasLowAlaPortn Client Trscv Bias Low :This OID
indicates that the Trscv laser
bias current of port is lower
than the threshold value written
in the Trscv EEPROM <Help> Alarm
indicating that… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.2.240.1.4 |
| pm10010ulhAlmTxBiasHighAlaPortn Client Trscv Bias High :This OID
indicates that the Trscv laser
bias current of port is higher
than the threshold value written
in the Trscv EEPROM <Help> Alarm
indicating th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.2.240.1.5 |
| pm10010ulhAlmVccLowAlaPortn Client Trscv Power Supply Low
:This OID indicates that the Trscv
power supply of port is lower than
the threshold value written in
the Trscv EEPROM <Help> Alarm
indicating th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.2.240.1.6 |
| pm10010ulhAlmVccHighAlaPortn Client Trscv Power Supply High
:This OID indicates that the Trscv
power supply of port is higher
than the threshold value written
in the Trscv EEPROM <Help> Alarm
indicating … | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.2.240.1.7 |
| pm10010ulhAlmTempLowAlaPortn Client Trscv Temp Low :This OID
indicates that the Trscv temperature
of port is lower than the threshold
value written in the Trscv EEPROM
<Help> Alarm indicating that the
Tr… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.2.240.1.8 |
| pm10010ulhAlmTempHighAlaPortn Client Trscv Temp High :This OID
indicates that the Trscv temperature
of port is higher than the threshold
value written in the Trscv EEPROM
<Help> Alarm indicating that the
… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.2.240.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| pm10010ulhAlmclientSfpAlmDdmIndex Index definition for the pm10010ulhAlmclientSfpAlmDdm
table | column | Integer32 | .1.3.6.1.4.1.20044.80.2.2.2.240.1.1 |