pm10010ulhAlmclientNetworkLaneAlarmWarningIndex
EKINOPS-Pm10010ulh-MIB ·
.1.3.6.1.4.1.20044.80.2.2.1.88.1.1
Object
column
Integer32
Index definition for the pm10010ulhAlmclientNetworkLaneAlarmWarning table
Context
- MIB
- EKINOPS-Pm10010ulh-MIB
- OID
.1.3.6.1.4.1.20044.80.2.2.1.88.1.1- Type
- column
- Access
- readonly
- Status
- current
- Parent
- pm10010ulhAlmclientNetworkLaneAlarmWarningEntry
- Table
- pm10010ulhAlmclientNetworkLaneAlarmWarningTable
- Siblings
- 16
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-128
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pm10010ulhAlmClientTxPowerLowAlarmPortn Client Trscv Tx Power Low Alarm
:This OID indicates that the Trscv
output power is lower than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that the… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.88.1.10 |
| pm10010ulhAlmClientTxPowerLowWarningPortn Client Trscv Tx Power Low Warning
:This OID indicates that the Trscv
output power is lower than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
that… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.88.1.11 |
| pm10010ulhAlmClientTxPowerHighWarningPortn Client Trscv Tx Power High Warning
:This OID indicates that the Trscv
output power is higher than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.88.1.12 |
| pm10010ulhAlmClientTxPowerHighAlarmPortn Client Trscv Tx Power High Alarm
:This OID indicates that the Trscv
output power is higher than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that t… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.88.1.13 |
| pm10010ulhAlmClientBiasLowAlarmPortn Client Trscv Bias Low Alarm :This
OID indicates that the Trscv laser
bias current is lower than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that t… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.88.1.14 |
| pm10010ulhAlmClientBiasLowWarningPortn Client Trscv Bias Low Warning
:This OID indicates that the Trscv
laser bias current is lower than
the threshold value written in
the Trscv EEPROM <Help> Warning
indicating th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.88.1.15 |
| pm10010ulhAlmClientBiasHighWarningPortn Client Trscv Bias High Warning
:This OID indicates that the Trscv
laser bias current is higher than
the threshold value written in
the Trscv EEPROM <Help> Warning
indicating … | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.88.1.16 |
| pm10010ulhAlmClientBiasHighAlarmPortn Client Trscv Bias High Alarm :This
OID indicates that the Trscv laser
bias current is higher than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.88.1.17 |
| pm10010ulhAlmClientRxPowerLowAlarmPortn Client Trscv Rx Power Low Alarm
:This OID indicates that the Trscv
input power is lower than the threshold
value written in the Trscv EEPROM
<Help> Alarm indicating that the
… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.88.1.2 |
| pm10010ulhAlmClientRxPowerLowWarningPortn Client Trscv Rx Power Low Warning
:This OID indicates that the Trscv
input power is lower than the threshold
value written in the Trscv EEPROM
<Help> Warning indicating that
… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.88.1.3 |
| pm10010ulhAlmClientRxPowerHighWarningPortn Client Trscv Rx Power High Warning
:This OID indicates that the Trscv
input power is higher than the
threshold value written in the
Trscv EEPROM <Help> Warning indicating
tha… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.88.1.4 |
| pm10010ulhAlmClientRxPowerHighAlarmPortn Client Trscv Rx Power High Alarm
:This OID indicates that the Trscv
input power is higher than the
threshold value written in the
Trscv EEPROM <Help> Alarm indicating
that th… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.88.1.5 |
| pm10010ulhAlmLaserTempLowAlarmPortn Client Trscv Laser Temp Low Alarm
:This OID indicates that the Trscv
Laser Temperature is lower than
the threshold value written in
the Trscv EEPROM <Help> Alarm
indicating t… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.88.1.6 |
| pm10010ulhAlmClientLaserTempLowWarningPortn Client Trscv Laser Temp Low Warning
:This OID indicates that the Trscv
Laser Temperature is lower than
the threshold value written in
the Trscv EEPROM <Help> Warning
indicati… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.88.1.7 |
| pm10010ulhAlmClientLaserTempHighWarningPortn Client Trscv Laser Temp High Warning
:This OID indicates that the Trscv
Laser Temperature is higher than
the threshold value written in
the Trscv EEPROM <Help> Warning
indica… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.88.1.8 |
| pm10010ulhAlmClientLaserTempHighAlarmPortn Client Trscv Laser Temp High Alarm
:This OID indicates that the Trscv
Laser Temperature is higher than
the threshold value written in
the Trscv EEPROM <Help> Alarm
indicating… | column | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.80.2.2.1.88.1.9 |